Philips 13PT30L1 Service Manual page 49

Color television
Table of Contents

Advertisement

Sub Menu: WHITE TONE
NORMAL
NORMAL RED
NORMAL GREEN 0 – 63
NORMAL BLUE
COOL
DELTA COOL RED
DELTA COOL
GREEN
DELTA COOL
BLUE
WARM
DELTA WARM
RED
DELTA WARM
GREEN
DELTA WARM
BLUE
White Tone Adjustments:
Note: The following procedure was performed with a Sencore VG91 Universal Video Generator providing grey
scale bars.
1. Enter the Service Alignment Mode (SAM) by pressing the following key sequence on the remote control
transmitter:
0-6-2-5-9-6-Status
Do not allow the display to time out between entries while keying the sequence.
2. From the top level SAM menu, use the Menu Up/Down keys to highlight the White Tone sub menu.
3. Use the Menu Left/Right keys to enter the White Tone sub menu.
4. Set the VG91 Generator as follows: STD TV Ch. 3, RF-IF Range set to HI, RF-IF Level set to NORMAL (1),
Video Pattern = Raster, R-G-B raster controls OFF.
5. Connect the RF output of the generator to the Television Antenna Input, and adjust the VG91 level to
remove any snow from the raster.
6. Turn off chroma at generator and leave grey scale bars.
7. From the White Tone sub-menu, use the Menu Up/Down keys to select Normal Red, Normal Green, or
Normal Blue. Then use the Menu Left/Right keys to adjust the values to obtain the best white balance.
8. A reasonable starting point for NORMAL is:
Normal Red=37, Normal Green=33, Normal Blue=35
9. After NORMAL is set, use the same method to set DELTA COOL and DELTA WARM as offsets.
A reasonable starting point for DELTA COOL is:
Delta Cool Red=0, Delta Cool Green=+1, Delta Cool Blue=+3
A reasonable starting point for DELTA WARM is:
Delta Warm Red=0, Delta Warm Green=-6, Delta Warm Blue=-5
10. After the values are set, or if no changes are required, press Menu to return to the top level SAM menu.
Value Range
Remarks
Starting Values:
0 – 63
32
23
0 – 63
25
Default Value
0
Delta values are a change of the normal values.
These start at the default values, and are set to
achieve cool and warm steps of color temperature in
the customer menu.
Standard factory settings are given as the default
values.
+1
+7
0
-4
-12