3-2. Special Notes on Repair Servicing

(1) External cover, scanner unit and FAU removal
(I) Remove the cassette, the front door (paper output tray), and the door damper.
- Pull out the cassette and remove it from the machine.
- Warp the front door up a little and push its right side downward to remove it from the bottom case.
- When removing the front door, remove the door damper from the hole of the bottom case.
(II) Remove the screws to detach the side cover from the main case.
- Remove the four screws from the back. Then, remove one screw from the upper left and one from the upper right,
and detach the side cover from the main case.
(III) Remove the front cover L and the side cover L.
- Front cover L: Be cautious not to contact the release lever to avoid a scratch or breaking claws.
- After removing the front cover, release the claws of the side cover and detach it from the main case.
- For the claw locations, see the photos below (indicated by the red circles).
- Remove the main case plate L (by removing one screw), and detach the side cover L.
- For the location of the claws on the side cover L, the main case, and the bottom case, see the photos below.
1-13