Type
.Solid-state power console using
. . . . . . . . . . . . . . .
Inputs
.Six input channels (high andlor
lnput Channel Controls. VOLUME, INPUT ATTENUATOR,
Aux Channel Controls. . .VOLUME, A/B PAN (700)
. . . . . .
Master Controls.
.MASTER, EFFECTS SEND, RE-
. . . . . . . . . . . . .
Outputs
.SPEAKER, MONITOR, EQ OUT,
. . .
Common Mix Buses
.MIX OUTPUT, EQ OUTPUT (A, B
. . . . .
Reverb and Effects
Built-in reverberation unit; provi-
Graphic Equalizers. . . . .lo-band, fully combining, mini-
. .
LED Status Indicators.
INPUT CLIP, DB PEAKIfeedback
Power Output
Per channel/4 ohms
Per channel/8 ohms
Measured at 1 kHz, 120 Vac, 1 % THD

SPECIFICATIONS*

discrete components and inte-
grated circuits
balanced low impedance), plus
two aux input channels (7
and 8)
A/B PAN (700), LOW and HlGH
FREQUENCY EQUALIZATION,
EFFECTSIREVERB, MONITOR
VERB LOW and HlGH EQUAL-
IZATION, REVERB RETURN,
MONITOR MASTER
MIX OUT, EFFECTS, HEAD-
PHONES, AUX, MIC
in 700)
sions for connection to remote
reverb on-off switch and exter-
nal effects devices
mum-phase, octave type, nor-
mally connected to power am-
plifier input; 13 dB boost or cut
at 63, 125, 250, 500 Hz, 1, 2, 4,
8 and 16 kHz; BELOW 63 Hz 12
dB/octave cutoff filter (10 dB
down at 31 Hz)
frequency, PA OVERLOAD,
POWER, TEMP WARNING,
SHUTDOWN
706; 700 with
700 with
both channels
one channel
driven
driven
200W min. 240W typical
125W min. 145W typical
. . . . . . . . . . .
Distortion
.THD typically less than 0.1% at
Low- and High-
Frequency lnput
. . . . . . . .
Equalization
?
lnput Clipping
. . . . . . . . .
.Light 3 dB below input or equal-
Indicators
DB Peak Indicators..
. . .
Indicate power amplifier peak
4-ohm load. Rise time: 250 @ec
PA Overload
. . . . . . . . .
.Light when power amplifier THD
Indicators
Temperature Warning
. . . . . . . . . .
Indicator
.Lights when output transistor
. . . .
Shutdown Indicator
Lights when power amplifier shut-
lnput Sensitivity
. . .
(full power output).
BAL LO IMP 0.6 mV
HI IMP
AUX
EQ INPUT
PA INPUT
40 Hz and 1 kHz, 0.25% at 15
kHz; IM distortion typically
less than 0.25% [One channel
driven, 180W or less to 4 ohms,
110W or less to 8 ohms, mea-
sured from low-impedance in-
put with individual and master
controls at typical settings
(orange index marks)]
13 dB at 100 Hz and 10 kHz
izer clipping level
voltage; +6 dB LED indicates
100 watts sine-wave output to
to full-scale indication; fall
time: 65 msec from full-scale to
no indication
exceeds 1 % ; fully on at 5%
temperature exceeds 70°C
(158°F)
down occurs due to output
transistor temperature over
100°C (212"F), air flow or fan
failure, or dc at speaker output
8 mV
21 5 mV (700)
106 mV (706)
960 mV
960 mV