Memory
Max: 8GB (2GB DIMM x 4)
Memory Slot
Standard Memory Module: 1GB (1GB DIMM x 1)
* Only one Memory Module can be ordered by CTO.
Memory Module Conversion kit (for CTO)
Memory Slot
*. Notes on installing memory
1. Memory is installed by one or more DIMMs.
2. The memory capacities of the slots should be in ascending order in the following sequence:
1A -> 1B -> 2A -> 2B
3. Available memory capacity depends on the type of OS and some memory area is used for PCI resource management.
The following table shows installed memory capacity and available memory capacity.
OS
Windows Server® 2008 Standard (32-bit)
Windows Server® 2003 R2, Standard Edition (SP2)
Windows Server® 2003, Standard Edition (SP2)
Windows® Small Business Server 2003 R2 (SP2)
Windows® Small Business Server 2003 (SP2)
Windows Server® 2008 Standard (64-bit)
Windows Server® 2003 R2, Standard x64 Edition (SP2)
Windows Server® 2003, Standard x64 Edition (SP2)
Red Hat Enterprise Linux ES (v.4 for x86)
Red Hat Enterprise Linux 5 (for x86)
Red Hat Enterprise Linux ES (v.4 for EM64T)
Red Hat Enterprise Linux 5 (for Intel64)
*1. If installed memory capacity is more than 2.0GB, it is necessary to set "PAE (Physical Address Extension)" of OS.
The following (1) and (2) are the ways to set "PAE" of OS, and Fujitsu recommends (1).
(1) Set "PAE" of OS.
Regarding setting "PAE" of OS, please refer to website of Microsoft.
(2) Set "DPE (Data Execution Prevention)" of CPU.
If "DPE" of CPU is set as "available" by executing the following procedure, "PAE" of OS is set automatically.
[1] Execute "BIOS setup utility".
[2] Select "Advanced" menu.
[3] Select "Advanced Processor" submenu.
[4] Set "NX Memory Protection" as "Enabled".
Connecting Internal HDD and Internal Backup Devices
If you would like to order internal HDD and internal backup devices, please order optional cards/cables according to the following table.
Type of HDD connection
Connection
Interface
SATA / RAID
Onboard SATA Controller
RAID
SAS RAID Controller
(''1) USB Backup Devices: PG-DT5043/PG-RD1021
[ 3.5inch SATA model ]
Internal HDD
SATA / RAID Configuration
on board
SATA
controller
*. 2 sets of RAID1 configuration can be set.
PCI Express
Bus
SAS RAID Ctrl w/ Cable
( 8ports / 256MB / without BBU )
PG-248BC
PGB248BC (for CTO)
*. RAID 0/1/1+0/5/6 configuration can be set.
Installed Memory
Capacity
~2.0GB
Same as installed memory capacity
2.0GB~4.0GB
2.0GB *1
~8.0GB
Same as installed memory capacity
Internal Backup Devices PRIMERGY ECONEL 100 S2
USB (''1) Connection
USB Cable (PG-CBLU005/PGBCBLU005)
Memory Module-1GB (1GB DIMM x 1)
PG-RM1BH
PGBRM1BH (for CTO)
Memory Module-2GB (2GB DIMM x 1)
PG-RM2BH
PGBRM2BH (for CTO)
Memory Module Conversion kit-2GB (2GB DIMM x 1)
PGBRU2BH2 (for CTO)
Available Memory Capacity
Max: 4 HDDs
HDD SATA 7.2k 80GB 3.5inch
PG-HDE87A
PGBHDE87A (for CTO)
HDD SATA 7.2k 160GB 3.5inch
PG-HDE67A
PGBHDE67A (for CTO)
HDD SATA 7.2k 500GB 3.5inch
PG-HDE57A
PGBHDE57A (for CTO)