Stepwise Start-up
Under normal circumstances, a fault in the power supply, or an
error during start-up, will switch the television to protection
mode. ComPair can take over the initialisation of the television.
In this way, it is possible to distinguish which part of the start-
up routine (hence which circuitry) is causing the problem.
Take notice that the transition between two steps can take
some time, so give the set some time to reach a stable state.
During the transition time the LED can blink strangely.
Stepwise start- up explanation
This is realised via ComPair and is very helpful when a
protection is activated (see also chapter "Protections").
Table 5-2 Stepwise start-up table
State Description mode
0
Low power standby:
5V2/3V3 present, uP in
standby-mode
1
High power Standby: TV-
set in standby-mode
2
Main Power On : HOP in
standby, 5V/8V present,
I2C protections on, SSB
is powered by standby-
supply (5V/8V). De-
gaussing (12 s) has been
activated, MSP is reset.
3
Initialized (Semi stand-
by): most IC's are initial-
ized, HOP still in standby
4
HOP : HOP fully pow-
ered and working, EHT is
present, rest of IC's ini-
tialized, black current
stabilisation is off, picture
is still blanked
5
On: TV-set operates,
black current stabilisa-
tion is on, picture is un-
blanked
Note (*):
When the set is in stepwise mode and, due to stepping-up,
a protection is activated, the set will really go into protection
(blinking LED). The set will not leave the stepwise-mode
however. If state X is the state where the set went to
protection, stepwise start-up will return to state X-1. At
state (X-1) diagnostic measurements can be performed.
Also, in the short time the set is in state X but not yet in
protection, you can also do some measurements.
5.4.4
How To Connect
1. First, install the ComPair Browser software (see the Quick
Reference Card for installation instructions).
2. Connect the RS232 interface cable between a free serial
(COM) port of your PC and the PC connector (marked with
"PC") of the ComPair interface.
3. Connect the mains adapter to the supply connector
(marked with "POWER 9V DC") of the ComPair interface.
4. Switch the ComPair interface "OFF".
5. Switch the television set "OFF" with the mains switch.
6. Connect the ComPair interface cable between the
connector on the rear side of the ComPair interface
(marked with "I2C") and the ComPair connector at the rear
side of the TV (situated just below the tuner input, see also
chapter 4).
Service Modes, Error Codes, and Fault Finding
EM5.1E
Display LED
Enabled
protection
On
None
Wait 1s, flash
None
1 x
Wait 1s, flash
4 & 5
2 x
Wait 1s, flash
Plus 1, 6 &
3 x
18
Wait 1s, flash
Plus 2 & 16
4 x
Wait 1s, flash
5 x
7. Plug the mains adapter in a mains outlet, and switch the
interface "ON". The green and red LEDs light up together.
The red LED extinguishes after approx. 1 second while the
green LED remains lit.
8. Start the ComPair program and read the "Introduction"
chapter.
Figure 5-2 ComPair Interface connection
5.4.5
How To Order
ComPair order codes (EU/AP):
Starter kit ComPair32/SearchMan32 software and
ComPair interface (excl. transformer): 3122 785 90450.
ComPair interface (excluding transformer): 4822 727
21631.
Starter kit ComPair32 software (registration version): 3122
785 60040.
Starter kit SearchMan32 software: 3122 785 60050.
ComPair32 CD (update): 3122 785 60110.
SearchMan32 CD (update): 3122 785 60120.
ComPair interface cable: 3122 785 90004.
5.5
Error Codes
5.5.1
Introduction
The error code buffer contains all detected errors since the last
time the buffer was erased. The buffer is written from left to
right, new errors are logged at the left side, and all other errors
shift one position to the right.
When an error has occurred, the error is added to the list of
errors, provided the list is not full or the error is a protection
error.
When an error occurs and the error buffer is full, then the new
error is not added, and the error buffer stays intact (history is
maintained), except when the error is a protection error.
To prevent that an occasional error stays in the list forever, the
error is removed from the list after 50+ operation hours.
When multiple errors occur (errors occurred within a short time
span), there is a high probability that there is some relation
between them.
5.5.2
How to read the Error Buffer
Use one of the following methods:
On screen via the SAM (only if you have a picture).
Examples:
0 0 0 0 0: No errors detected
6 0 0 0 0: Error code 6 is the last and only detected
error
9 6 0 0 0: Error code 6 was first detected and error
code 9 is the last detected error
Via the blinking LED procedure (when you have no
picture). See next paragraph.
Via ComPair.
EXTERNAL 2
L
R
AUDIO
EXTERNAL 1
SERVICE
CONNECTOR
I 2 C
PC
VCR
Power
CL96532156_029.eps
9V DC
190600

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

28pw952832pw952836pw9528

Table of Contents