Pin Configuration; Circuit Description - Honeywell HMR4007 User Manual

Honeywell hmr4007 linear position sensor user's guide
Table of Contents

Advertisement

HMR4007

PIN CONFIGURATION

Pin Number
Digital Interface
1
2
3
4
5
6
Analog Interface
1
2
3
4
Jumper Block #1
2-5
3-6
Note 1:
The board contains three interface connectors for digital and/or analog communications. Power is supplied to the board
through any one of these connectors and is selected by jumper block #1. All of the ground connections on all three
ports are common to the circuit ground and are not affected by the jumper position. Only ONE of the three positions on
JP1 should be shorted at a time. Shorting more than one may result in excessive power supply currents and board
damage.

CIRCUIT DESCRIPTION

The HMR4007 Linear Position Sensor circuit board includes all of the basic sensors and electronics to provide a
digital indication of position of a target magnet. The HMR4007 starts with an array of seven Honeywell HMC1501
single axis magnetoresistive (MR) sensors to determine the field geometry and direction of a target magnet attached
to the moving part of a device under test. These sensors are supplied power by a constant voltage source, and the
use of an array of sensors helps to maintain accuracy over temperature and run-out. The sensor outputs are routed
to a multiplexed Analog to Digital Converter (ADC) integrated circuit. A microcontroller integrated circuit periodically
queries the multiplexed ADC and performs sensor offset and gain corrections and computes the position of the target
magnet as a function of the distance of travel along the long axis of the sensor board. The position data, along with
an error bit, is available thought the serial interface or is present on the Digital to Analog Converter (DAC) output port.
The serial interface is not needed in order to use the board's stand-alone analog output. The microcontroller
also performs the external serial data interface and other housekeeping functions. An onboard EEPROM integrated
circuit is employed as a nonvolatile storage to retain necessary data and configuration variables for best performance.
The HMR4007 uses an on-board low drop out (LDO) +5 volt regulator so that a regulated +5 volt power supply or an
unregulated power supply in the range of +6VDC to +28VDC can be used. The power is supplied to the board
through one of the three user ports being (serial, analog, or USB) and a jumper is used to select which port is the
power source. Only one jumper should be in place at any one time as the board does not have over current
protection and use of more than one jumper can result in excessive power supply currents and board damage.
Solid State Electronics Center
Pin Name
RTS
Serial Clock Output
Data_Out
Serial Data Output
Data_In
Serial Data Input
CTS
Serial Clock Input
Power
Unregulated Power Input (+6 to +28 VDC) (see note 1)
GND
Power and Signal Ground
Power
Unregulated Power Input (+6 to +28 VDC) (see note 2)
Analog Out
0 - 2.5 VDC analog output
Position Valid
TTL level (0 = position invalid, 1 = position valid)
GND
Power and Signal Ground
Note 1
Analog Output port selected as power source
Note 1
Serial Communications port selected as power source
www.magneticsensors.com
Description
(800) 323-8295
Page 4