Tatung Vibrant VM77S Service Manual page 12

17-inch color monitor
Table of Contents

Advertisement

Q433, R436, R497, R459, C482 to control I501 pin 22 voltage. When I501 pin 22 voltage drops
below 4.1 V, the ABL function will happen.
3-3-8 H/V size breathing compensation
1. Beam current is sensed as above section (3-3-7 item 2) and this voltage routes through R451, R468, C470
then through R437 to I401 pin 31 for H. size compensation.
2. HV voltage is detected through T402(FBT) pin 11. C481, R4F4, R4F8, R4F9, Q428, R4G0, Q431, R4G1,
then through R302 to I401 pin 21 for V. size compensation.
3-3-9 Dynamic focus circuitry
The dynamic focus is applied to improve the corner focus performance, it includes horizontal and vertical
dynamic focus.
1. Horizontal dynamic comes from C413 through R435, C450, T401, R434, C448 and feed to FBT dynamic
focus pin (T401 pin 12).
2. Vertical dynamic comes from I401 pin 32 through C315, R322, R326, R321, R323, Q301, R324, R325 and
feed to FBT dynamic focus pin.
3-4 Power Supply Section
3-4-1
AC Rectifier
The circuit can accept 90 V to 264 V AC input through D801~D803 bridge diodes and C808 filtering to get
DC 126 V~364 V for power conversion in T802.
3-4-2
Line Filter
It consists of C803, T801, C804, C805, C808, C819, C807, C817 and meets EMI regulation.
3-4-3
Power LED Status
1. The LED has 3 leads with common cathode to emit green and amber color light for different power
saving states. It is controlled by CPU.
2. Normal : Green light
Amber LED is off because CPU pin 30 is 1.96V and pin 31 is 0.45V, only green LED is turned on.
3. Off Mode : Amber light
CPU pin 30 is 1.87V and pin 31 is 0.46V, then green is off and amber is illuminated.
3-4-4 Auto Degaussing
When S801 turns on, pin 14 of I701 will send a signal to Q802 and turns on RL801 for degaussing. After 4
seconds, it will turn off RL801 automatically.
3-4-5 PWM Control
1. Start Up
The I801 (5S0765C) gets power from R807, R808, C830 and pin 3 voltage reaches 15 V for starting up.
The I801 starts oscillation at 20 kHz, pin 1 output to drive T802. Switching on, R819 set up an 15 V to
keep I801 working through D809 auxiliary voltage.
VM77S

Advertisement

Table of Contents
loading