Installation: M7215, M7415, M8405 - Honeywell C7150B Product Data

Solid state economizer system
Hide thumbs Also See for C7150B:
Table of Contents

Advertisement

IMPORTANT
All inputs and outputs must be 24 Vac Class 2.
Ambient Ratings:
Temperature: -40°F to +149°F (-40°C to +65°C). Humidity: 5 to
95 percent RH (noncondensing).
Inputs:
Enthalpy (C7400)
Dry Bulb Temperature (C7650)
Discharge Air (C7046)
Mixed Air (C7150)
DCV Sensor (C7232): 0/2-10 Vdc control signal;
100K ohm input impedance.
Outputs:
Actuator Signal: 2-10 Vdc. Minimum Actuator Impedance: 1K
ohm.
Exhaust Fan: Contact closure.
24 Vac Out: 25 VA maximum.
Approvals:
Underwriters Laboratories Inc.: UL873 listed.
Flammability Rating: UL94-5VB.
Plenum Rated.
CE.
C-tick.
Accessories:
4074EJM Bag Assembly. Consists of: Checkout jumper, 620
ohm, 1.2K ohm, 5.6K ohm, and 6.8K ohm checkout resis-
tors.
C7046A Discharge Air Temperature Sensor. C7150B Mixed Air
Temperature Sensor.
C7232A,B Carbon Dioxide Sensors.
Control Range
Model
Number
°F
T6031H
0° to 95°
-18° to +35° 150°
For Use with
Model
Actuator
W7459A
M7415
W7459C
M8405
W7212A
M7215
MS7505

INSTALLATION: M7215, M7415, M8405

When Installing this Product...
1. Read instructions carefully. Failure to follow them could
damage the product or cause a hazardous condition.
2. Check ratings and description given in the specifications
to make sure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
Table 2. T6031H Thermostat Specifications.
Max Element
Temperature
°C
°F
°C
66°
Table 3. W7459A,C,D Specifications.
Discharge Air
Temperature Input
Potentiometer Adjustment
Thermistor Sensor
Yes
Spst control
No. Minimum position
adjustment is built into
M8405 Actuator
Thermistor sensor
Yes
C7400 Solid State Enthalpy Sensor.
C7650 Dry Bulb Temperature Sensor.
S963B1128 Remote Potentiometer to provide remote control of
damper minimum position.
ST6008 Energy Management Timer for occupied/unoccupied
control.
2-1/16
(53)
1-15/16
(49)
1/8 (4)
Fig. 7. Logic module dimensions in in. (mm).
Differential
Type of
°F
°C
Mounting
Back
Minimum Position
Minimum Damper Position
Yes
No
Yes
4. After installation is complete, check out product opera-
tion as provided in these instructions.
CAUTION
Electrical Shock or Equipment Damage Hazard.
Can shock individuals or short equipment circuitry.
Disconnect power supply before installation.
7
SOLID STATE ECONOMIZER SYSTEM
4-3/8 (112)
2-5/8 (66)
Capillary Length
ft
m
in.
2
0.6
3/8 x 3-1/2
Terminals for Remote
1-5/8
(41)
4-1/8
(104)
M20578B
Bulb Size
mm
10 x 89
Output
Relays
2 spdt
2 spdt
2 spdt
63-2484—2