21. Repeat above procedure (item 5,6,7) until chroma 7120 RGB value meet the tolerance =100±2
22. Move cursor to " Exit/Save" sub-menu and press MENU key to save adjust value and exit.
Turn the POWER-button off to on to quit from factory mode.
Max Brightness measurement:
a. Switch to the full white pattern, in user mode main menu:
1. Set <Color Settings> Red, Green, and Blue to the max.
2. Set <Brightness> Brightness, Contrast to the max.
b. The Minimum brightness is 200cd/m

11. EDID Content

00
01
0:
00
FF
16:
0D
0F
32:
11
4F
48:
01
01
64:
13
00
80:
32
33
96:
45
4C
112:
00
38
Note: Byte 0C, 0D, 0E, 0F means Serial No. Byte 10, 11 means manufacture time. Byte
7F means checksum
2
.
±20
02
03
04
05
FF
FF
FF
FF
01
03
68
22
54
A5
4B
00
01
01
01
01
52
0E
11
00
35
34
36
38
4C
20
45
31
4B
1F
50
0E
06
07
08
09
FF
00
10
AC
1B
78
EE
CA
71
4F
81
80
30
2A
00
98
00
1E
00
00
37
39
30
0A
37
36
46
50
00
0A
20
20
49
10
11
12
13
14
A0
30
39
F6
A3
57
47
01
01
01
01
51
00
2A
40
00
FF
00
39
00
00
00
FC
0A
20
00
00
20
20
20
20
Dell E176FPc
14
15
37
38
9E
23
01
01
30
70
30
31
00
44
00
FD
00
4B