Download Print this page

American Standard Selectronic Proximity Toilet Flush Valve 065.525 Installation Instructions Manual page 8

Proximity toilet flush valve 1.28 & 1.6 gpf

Advertisement

HOW TO SET DETECTION RANGE
10
(If Required) ; Fig. 13 & 14
Note: The detection distance is preset and is ideal for
most installations. Should an adjustment be required
follow the steps below.
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2)
in back of top half of FLUSH VALVE (3). Fig. 13a.
2. Rotate CAP (3) to the right and pull off. Fig. 13b.
3. Turn CAP (3) over and disconnect GREY SENSOR
WIRE (4) from BATTERY COVER (5).
4. Keeping hands away from the front of the sensor,
reconnect the GREY SENSOR WIRE (4) and quickly
place the CAP (3) on the valve. Do not secure the CAP
(3) at this time. Note: You have 5 seconds after
connecting cable to enter program code.
5. While the SENSOR CONTROL LED (6) is blinking
slowly, place your hand 1 to 2 in. (30-50mm.) in front of
the sensor. Fig. 14a.
6. When the LED (6) stops blinking and stays "ON",
move your hand to the desired position from sensor
(detection zone, 1-1/2" to 31", 38 to 787mm ) and hold
in place until the LED (6) begins to blink again. Fig. 14b.
Note: Detection Zone is 1-1/2" to 31", 38 to 787mm
from sensor.
7. Once the SENSOR CONTROL LED (6) begins to
blink again, remove your hand from the detection zone.
When the flashing stops, the detection distance is set.
8. Replace and secure CAP (3) onto valve.
9. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds. NOTE:
Stand outside of sensor detection aera.
B) Remove hand from in front of the sensor; unit will
flush in approximately 3 seconds.
Fig. 14
6
BLINKING LED
Fig. 14a
1" - 2" (30mm - 50mm
Fig. 13
Fig. 13a
2
Fig. 13c
3
5
4
Fig. 14b
7
Fig. 13b
1
VIEW "A"
VIEW "A"
DETECTION ZONE
38mm TO 787mm
(1-1/2 TO 31)
6
BLINKING LED
M968699 Rev. 1.3
6
3

Advertisement

loading