Download Print this page

American Standard Selectronic Proximity Toilet Flush Valve 065.525 Installation Instructions Manual page 5

Proximity toilet flush valve 1.28 & 1.6 gpf

Advertisement

FLUSH OUT SUPPLY LINES; Fig. 6
4
1. Remove COVER (1) from SUPPLY STOP (2).
2. With a flat blade screwdriver open SUPPLY STOP (2).
3. Turn on water supply to flush line of any debris or
sediment.
4. Close SUPPLY STOP (2) and replace COVER (1).
4 LEFT OR RIGHT HAND
5
3
INSTALLATION; Fig. 7
The UNIT is shipped with the inlet flange on the right
side. If needed, the orientation can be reversed by
following the steps below.
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (4)
in back of top half of FLUSH VALVE (2). Fig. 7a.
2. Rotate TOP (2) to the right and pull off. Fig. 7b.
3. Rotate bottom half of FLUSH VALVE (3) 180˚. Fig. 7b.
4. Replace TOP (2) and rotate until key engages than
tighten SET SCREW (1). Fig. 7c, 7d.
Fig. 6
CLOCKWISE CLOSES
CONTROL STOP
Fig. 7
2
1
4
Fig. 7a
2
Fig. 7c
Fig. 7d
4
2
REMOVE COVER
1
2
COUNTER-CLOCKWISE
OPENS CONTROL STOP
BLACK-
3
Fig. 7b
180˚
KEY
4
1
M968699 Rev. 1.3
2
RED+

Advertisement