TK-863G
Item
Condition
10. DQT
1) Set test mode
deviation
Select "FDQT" in tuning mode. Deviation
• Wide
"F.DQT"
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
2) "F.D.Q.T"
PTT : ON
Adjust [ *** ]
3) "F.D.Q.T._."
PTT : ON
Adjust [ *** ]
• Narrow
4) "FDQT *** ."
PTT : ON
Adjust [ *** ]
11. LTR
1) Set test mode
deviation
Select "FLTR" in tuning mode.
• Wide
"F.LTR"
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
2) "F.L.T.R"
PTT : ON
Adjust [ *** ]
3) "F.L.T.R._."
PTT : ON
Adjust [ *** ]
• Narrow
4) "FLTR *** ."
PTT : ON
Adjust [ *** ]
12. DTMF
1) Set test mode
deviation
Select "DTMF" in tuning mode.
• Wide
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
• Narrow
2) "DTMF *** ."
PTT : ON
Adjust [ *** ]
44
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Front
panel
panel
meter
Oscilloscope
AF VTVM Front
MIC
AG
panel
Adjustment
Parts
Method
/
0.75kHz
50Hz (Wide/Narrow)
0.375kHz
1.0kHz
50Hz (Wide/Narrow)
0.75kHz
3.0kHz
0.2kHz
1.5kHz
0.1kHz
Specifications/Remarks