3. Insert the pillow (47) into the lounge seat recepta-
cle. The pillow can be rotated 180º to change
between the high or low positions.
4. The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 240 volt Ground
Fault Circuit Interrupter (GFCI) installed in your home. This procedure must be performed by a qualified,
licensed electrician. A wiring diagram is found on the inside of the electronics package for reference.
Under no circumstances should the spa be wired by someone other than a qualified electrician. Before
you have the spa wired, make sure it is in the desired position, and that it can be easily serviced, if needed.
5. Make sure that a qualified electrician has wired the
spa to a 240 volt power source.
Remove the two warning decals (see page 5) from
the spa shell. Using a damp cloth, wipe the spa shell
clean. Before filling the spa, make sure that it is
in the desired position and that there is room to
easily service it. Once the spa is filled, it will
have to be drained before it can be moved.
Using a garden hose or other clean water source,
begin filling the spa. Do not use soft water. The
spa may be filled with cold water; however, if warm
or hot water is used, the spa will be ready for use
sooner. Fill the spa until the water is at the level
shown at the right. Do not overfill the spa.
Refer to the inset drawing. Set the Filters (5) into the
filter housings. Next, screw the Filter Covers (3) into
the filter housings until they are fully seated.
6. Pull down one of the straps on the Spa Cover (11)
and hold the Buckle (26) against one of the premium
cedar panels on the spa. (Note: To position the
Buckle correctly, have a second person hold the
strap on the opposite side of the Spa Cover snug.)
The Spa Cover must be snug. Do not place the
Buckle over the grooves between the premium
cedar panels. Refer to the inset drawing. Remove
the latch from the Buckle (26). Attach the Buckle to
the premium cedar panel with two #4 x 3/4" Screws
(27).
Attach the other three Buckles (26) to the premium
cedar panels in the same way.
Remove the Spa Cover (11) from the spa.
3
47
5
Fill to Here
Garden Hose
6
11
9
3
5
Strap
Latch
26
27
Strap
26