Kenwood TK-2180 Service Manual page 33

Hide thumbs Also See for TK-2180:
Table of Contents

Advertisement

Item
Condition
6. Low power
1) Adj item : [LPWR]
adjust
Adjust : [✳✳✳]
2) Adj item : [L LPWR] →
[L' LPWR] → [C LPWR] →
[H' LPWR] → [H LPWR]
Adjust : [✳✳✳]
PTT : ON
7. Low power
[Panel test mode]
check
1) CH-Sig : 1-1
Set low power (Push [S])
PTT : ON
2) CH-Sig : 2-1
PTT : ON
3) CH-Sig : 3-1
PTT : ON
8. DQT balance 1) Adj item : [n BAL]
adjust
Adjust : [✳✳✳]
Deviation meter filter
LPF : 3kHz
HPF : OFF
2) Adj item : [nL BAL] →
• Narrow
[nC BAL] → [nH BAL]
Adjust : [✳✳✳]
PTT : ON
• Wide 4k
3) Adj item : [s BAL]
Adjust : [✳✳✳]
PTT : ON
• Wide 5k
4) Adj item : [w BAL]
Adjust : [✳✳✳]
PTT : ON
9. Max DEV
1) Adj item : [n DEV]
adjust
Adjust : [✳✳✳]
AG : 1kHz/75mV at MIC terminal
Deviation meter filter
LPF : 15kHz
HPF : OFF
2) Adj item : [nL DEV] →
• Narrow
[nC DEV] → [nH DEV]
Adjust : [✳✳✳]
PTT : ON
• Wide 4k
3) Adj item : [s DEV]
Adjust : [✳✳✳]
PTT : ON
• Wide 5k
4) Adj item : [w DEV]
Adjust : [✳✳✳]
PTT : ON
10. MIC
[Panel test mode]
sensitivity
1) CH-Sig : 1-1
check
AG : 1kHz/5.0mV at MIC terminal
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Panel
ANT
Panel
Ammeter
Panel
ANT
Panel
Deviation
Universal
meter
connector
Oscilloscope
AG
AF VTVM
TK-2180
Adjustment
Parts
Method
± 0.1W
Selector 1.0W
knob
1.0A or less
Check
0.7~1.4W
1.2A or less
Selector Make the demodu-
knob
lation waves into
square waves.
± 50Hz
2.10kHz
(According to the
larger +, –)
± 50Hz
3.35kHz
(According to the
larger +, –)
± 50Hz
4.20kHz
(According to the
larger +, –)
Check
0.9~1.4kHz (Narrow)
1.3~2.2kHz (Wide 4k)
1.5~2.7kHz (Wide 5k)
Specifications/Remarks
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents