Worcester GREENSTAR 24i junior Instruction Manual page 41

Wall hung rsf gas fired condensing combination boiler, for sealed central heating systems and mains fed domestic hot water
Table of Contents

Advertisement

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
8 716 115 166b (03/2009)
INSPECTION AND SERVICE
5
H
4
Remove electrical connector from fan.
5
Undo and remove securing nut (H) from the
top of the heat exchanger.
6
Remove retaining plate I).
7
Rotate fan and air/gas manifold assembly (J)
around the top of the heat exchanger until it
stops at the lug.
Lift up assembly and remove from boiler.
8
Disconnect spark electrode and flame sensor
connections (K).
6
Remove clamping plate (L).
Remove spark/flame electrode assembly
I
from boiler.
Remove seal from the top of the heat
exchanger.
4
K
INSPECTION AND SERVICE
8
L
7
J
41