LG GR-L207WVS Service Manual page 50

Sxs refrigerator
Table of Contents

Advertisement

EXPLATION FOR MICOM CIRCUIT
2) GR-C247, B247, C207, B207,GR-B197
FRZ TEMP
REF TEMP
2. Sensor resistance characteristics table
Measuring Temperature (°C)
-20 °C
-15 °C
-15 °C
-5 °C
0 °C
+5 °C
+10 °C
+15 °C
+20 °C
+25 °C
+30 °C
+40 °C
+50 °C
u Resistance value allowance of sensor is ±5%.
u In measuring resistance value allowance of sensor, perform measuring after leaving the sensor for more than 3 minutes
at the measuring temperature (delay is required due to sense speed relation relationship).
u Since an analog tester has a large measuring temperature, measuring with a digital tester is required as possible as.
u Resistance of the cold storage sensor 1 and 2 shall be measured with a digital tester after separating CON8 of the PWB
ASSEMBLY and the MAIN part.
u Resistance of the freezing sensor shall be measured with a digital tester after separating CON7 of the PWB ASSEMBLY
and the MAIN part.
MIN
TEMP
MIN
TEMP
Freezing Sensor
22.3 kΩ
16.9 kΩ
13.0 kΩ
10.1 kΩ
7.8 kΩ
6.2 kΩ
4.9 kΩ
3.9 kΩ
3.1 kΩ
2.5 kΩ
2.0 kΩ
1.4 kΩ
0.8 kΩ
- 50 -
MAX
ROOM
TEMP
MAX
OFF
Cold storage sensor 1, 2.
Frost removal sensor, Outside sensor
77 kΩ
60 kΩ
47.3 kΩ
38.4 kΩ
30 kΩ
24.1 kΩ
19.5 kΩ
15.9 kΩ
13 kΩ
11 kΩ
8.9 kΩ
6.2 kΩ
4.3 kΩ
LOCK
SUPER FRZ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents