Memory Error Events
Table 2-2. Memory Error Events
Byte
Field
01:02
Record ID
3
Record Type
04:07
Time Stamp
08:09
Generator ID
10
EvM Rev
11
Sensor Type
12
Sensor Number
13
Event Dir | Event
Type
14
Event Data 1
Value
XXXXh
02h
XXXXXXXXh
0100h
04h
0Ch
7A/7B/7C/7Dh
6Fh
0A0h
Using the System Setup Program
Description
ID Used for SEL Record access
02h = system event record
Time when event was logged
Generated by BIOS
Event Message Format Revision.
04h for this specification
Sensor type code for sensor that
generated the event
Number of Sensor that generator
the event
DIMM A1:7Ah
DIMM A0:7Bh
DIMM B1:7Ch
DIMM B0:7Dh
Bit 7 0 = Assert Event
Bit 6:0 Event Type Code
Bit 7:6 10b = OEM code in byte 2
Bit 5:4 10b = OEM code in byte 3
Bit 3:0 Offset from Event/Reading
Code for discrete
event status
0h Correctable Error
1h Uncorrectable Error
5h Correctable ECC error logging
limit reached.