CONTROL & FEATURES

Voltage Selector Switch

The voltage selector switch switches generator output to produce ''120
V ONLY'' or ''120/240V''. If a 240V appliance is connected to the 4-
prong receptacle, the switch must be in the ''120/240V'' position. If
only a 120V appliance is being connected to any of the 120V 3-prong
receptacles, select the ''120V ONLY'' position.
Select the voltage before starting the engine.
Switch Position
120/240V:
The 120V and 120/240V receptacles can be used
simultaneously.
120V ONLY:
ONLY the 120V receptacles can be used. Do not use the
120/240V receptacle in this position. The most power will be available
at the 30A 120V locking plug receptacle.

AC Circuit Protectors

The AC circuit protectors will automatically switch OFF if there is a
short circuit or a significant overload of the generator at each
receptacle. If an AC circuit protector switches OFF automatically, check
that the appliance is working properly and does not exceed the rated
load capacity of the circuit before resetting the AC circuit protector ON.
CIRCUIT PROTECTOR
for Receptacle
CIRCUIT PROTECTOR
for Receptacle
120V 30A
120V 20A
14
CIRCUIT PROTECTOR
for Receptacle
120V 20A
VOLTAGE SELECTOR SWITCH
CIRCUIT PROTECTOR
for Receptacle
120/240V 30A
120V/240V
120V ONLY
AC CIRCUIT PROTECTOR
ON
OFF
PUSH