STORAGE
Before storing the unit for an extended period:
1.
Be sure the storage area is free of excessive humidity and dust.
2. Service according
to the table below:
STORAGE TIME
No
preparation required
Less than 1 month
RECOMMENDED SERVICE PROCEDURE TO
1 to 2 months
Fill with fresh gasoline and add gasoline
conditioner
*.
Fill with fresh gasoline and add gasoline
2 months to 1 year conditioner
*.
Drain the carburetor float bowl. (page
44).
Drain the fuel sediment cup. (page 37).
Fill with fresh gasoline and add gasoline
conditioner
*.
Drain the carburetor float bowl. (page
44).
Remove the spark plug. Put a tablespoon of
engine oil into the cylinder. Turn the engine
slowly with the starter grip to distribute the
oil. Reinstall the spark plug.
Change the engine oil. (page 35).
After removal from storage, drain the stored
gasoline into
a suitable container, and
fill
with fresh gasoline before starting.
*
Use gasoline conditioners that are formulated to extend storage
life.
Contact your authorized Honda generator dealer for conditioner
recommendations.
PREVENT HARD STARTING
1 year or more Drain the fuel sediment