Download Print this page
Siemens SMP16-SV430 Technical Specifications
Siemens SMP16-SV430 Technical Specifications

Siemens SMP16-SV430 Technical Specifications

Power supply

Advertisement

Quick Links

Power Supply SMP16-SV430
Order No: 6AR1306-0DC00-0AA0
FEATURES
Offline power supply unit with output for +15 V and –15 V
Input voltage range 94 to 264 V AC
Softstart: No U
overswing at switch-on
a
Slide-in module for 19-inch subrack (for individual locking)
WARNING NOTES
Trouble-free and safe operation of the unit is dependent on proper
transport and storage, as well as installation by qualified personnel.
Installation of the device requires that the applicable DIN/VDE
regulations or the safety regulations of your country be adhered to.
Warning
Protective ground (PE) must be connected with the
protective conductor of the power network of the power
company.
Caution
The device may only be used within the permitted input
voltage range.
Danger of electric shock
Since certain parts of electrical devices inevitably carry
dangerous voltage when these devices are operated,
incorrect handling of these devices may cause death or
serious injury as well as substantial property damage.
Caution
Electrostatic Sensitive Device (ESD)
CONNECTOR ASSIGNMENT
4
1)
1)
6
1)
8
1)
10
1)
12
+15VL
14
0VL
16
0VL
18
1)
20
-15VL
22
24
2)
2)
26
L
28
N
30
PE
32
Caution
The counter plug connector must be equipped with tin-
plated contacts.
INSTALLATION
The power supply may only be mounted and wired by qualified
personnel who are familiar with and observe the general rules of
this technology and the applicable regulations and standards.
This board may only be installed or removed when the voltage
is off.
©SIEMENS A&D SE
(ES4/Ka/WW8.0/A4)
Signal Description
L, N
Input voltage
PE
protective conductor,
leading pin
1)
Used internally.
Do not connect.
2)
Protective conductor
potential
+15VL
Output voltage 1
–15VL
Output voltage 2
0VL
GND for outputs
C8451-A6-A83-4-7418
Product Release Letter (English)
To ensure proper ventilation, the device must be mounted vertically
so that the ventilation slits are pointing up or down. A free space of
at least 5 cm must be provided both above and below the device so
that convection is not obstructed.
Parallel circuiting of the outputs of several power supply boards is
not permitted.
For more information on installing and handling SICOMP boards,
see SICOMP IMC System Manual.
STANDARDS/CERTIFICATIONS
Galvanic isolation input/outputs
Test voltage
Electromagnetic compatibility
Power feedback
Interference emission
(EN 50081-1)
Interference immunity
(EN 50082-2)
Certifications
TECHNICAL SPECIFICATIONS
Input
Input voltage range
Input frequency
Efficiency η
Operation indicator
Outputs
Rated output voltage U
Tolerance on delivery
Temperature coefficient
Deviation, dynamic:
Recovery time for 0.2 to 0.8 x I
Residual ripple:
Total interference voltage
Switch-on delay
Power failure bypass
Rated output current I
Overload protection at:
Overvoltage protection
Ambient conditions
Permissible ambient temperature
- during operation:
- during transport/storage:
Power reduction above 50 °C
Relative air humidity:
Degree of protection (EN 60529)
Degree of protection (VDE 0106
Part 1)
General Specifications
Design:
Plug connector (male connector):
Weight:
Dimensions:
- Width
- Height
- Length
24.01.2003
2.5 kV AC
SELV in acc. w. EN 60950
Overvoltage category II
Class A in acc. w.
EN 61000-3-2
Class B in acc. w. EN 55022
in reference system
EN 61000-4-2/3/4/5/11
CE
94 ... 264 V AC
50/60 Hz
80%
LED
Continuous short circuit
protected, idle-proof
Output 1
+15 V DC
AN
±5%
≤ 0.025% / K
±0.2%
< 0.5 msec
AN
< 20 mV
< 50 mV
1 s
40 msec at 100% load
1.5 A
AN
ca. 2.2 A
125% ±5% automatic return
0 °C to +55 °C
–25 °C to +85 °C
2.5% / K
5 to 90%, no condensation
IP 20
19" plug-in unit,
individual locking
DIN 41612-H15, tin plated
approx. 0.5 kg
8 TE (2 slots)
3 HE
160 mm
Output 2
–15 V DC
ss
ss
1.5 A
I
1

Advertisement

loading

Summary of Contents for Siemens SMP16-SV430

  • Page 1 Product Release Letter (English) To ensure proper ventilation, the device must be mounted vertically Power Supply SMP16-SV430 so that the ventilation slits are pointing up or down. A free space of Order No: 6AR1306-0DC00-0AA0 at least 5 cm must be provided both above and below the device so that convection is not obstructed.
  • Page 2 Product Release Letter (English) SMP16-SV430 Fehler! Verweisquelle konnte nicht gefunden werden. ©SIEMENS A&D SE C8451-A6-A83-4-7418 (ES4/Ka/WW8.0/A4)