HP ProLiant DL380 Generation 7 (G7) Quickspecs page 7

Generation 7
Table of Contents

Advertisement

QuickSpecs
Standard Features
Server Power Cords
Common Slot Power
Supply
System Fans
Required Cabling
High voltage power cord ships standard with all part numbers.
NOTE: HP ProLiant DL servers no longer ship standard with a 12-foot NEMA 5-15P to C13 power cords that
allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected
to PDU's in data center racks so they now ship standard with only a PDU 6-foot C-14 to C13 power cord
(142258-001). If a user wishes to power a ProLiant DL server using a110V receptacle (NEMA-15), the 12-
foot NEMA 5-15 to C13 power cord must be ordered separately. Also available: 110 volt 6-Foot NEMA 5-
15p to C13 (AF556A).
Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new
Common Slot power supplies are designed to provide the highest power supply efficiency without
degrading the performance of a ProLiant. CS Power Supplies have efficiency ratings of up to 94% and are
available in three power output options allowing the customer to "right-size" a power supply for their
specific server configuration. To make sure you select the correct power supply to meet your configuration
needs, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All
HP Common Slot power sources are UL, CE Mark Compliant, hot-plug and support redundant
configurations.
NOTE: Mixing of power supplies in the same server is not supported. All power supplies must be of the
same output and efficiency rating. If non-matched power supplies are inserted you will get errors and
operation will fail.
It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for
your needs. HP Power Advisor can be accessed at: www.hp.com/go/hppoweradvisor.
NOTE: The 80 PLUS program is a unique forum that unites electric utilities, the computer industry, and
consumers in an effort to bring energy efficient technology solutions to the marketplace. 80 Plus
independently tests power supply efficiency and publicly posts the results on 80Plus.org.
Redundant Power: Optional (1+ 1 or n+n redundant) power supplies can be purchased through power
supply option kits (see Power Supplies for part numbers).
Fully redundant hot plug fans ship standard (N+1).
NOTE: One processor models include four fans. Two processor models include six fans.
For required cabling information, refer to the HP Web site at: www.hp.com/servers/dl380.
DA - 13595 Worldwide — Version 65 — March 25, 2013
HP ProLiant DL380 Generation 7 (G7)
Page 7