SUB-TS7/TS8
Parameter
Turn-off Transient
Efficiency
Stand-by Input Power
Power Consumption @ rated powe
Protection
Short Circuit Protection
Thermal Protection
DC Offset Protection
Primary Fuse Rating
USA-Domestic (120V)
Nonimal
QA Test
Unit
Specification
Limits
100
50
mV-peak
10
Watts
12
200
170
Watts
YES
functional Direct short at output
YES
functional
YES
functional DC present at Speaker Out leads
n/a
2.5
Amps
Conditions
@ Speaker Outputs
@ nom. line voltage
@ nom. line voltage
Type-T or Slo Blo
3
harman/kardon
Notes
AC Line cycled from ON to OFF
Maximum allowable input power under nominal
input voltage and frequency, in stand-by mode (HOT
or COLD operation).
100 Watts @ 4.0 ohms and nominal line voltage
Amplifier should resume operation after short circuit
condition is removed.
Any user accessible metal parts should always
remain at 65 degree C or less for domestic version
or 55 degree C or less for EU version.
Relay or crowbar (for driver/fire protection),
User-replacable fuse with UL/SEMCO rated holder.