Fujitsu PRIMERGY RX200 S2 User Manual page 62

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Hexad
ecimal
ID
notatio
n
34
(0x22)
35
(0x23)
36
(0x24)
37
(0x25)
38
(0x26)
39
(0x27)
40
(0x28)
62
Type
Log item
Error
A physical disk
failed because SCSI
bus reset failed.
Error
A physical disk
failed because
double check
condition occurred.
Error
A physical disk
failed because
device is missing.
Error
A physical disk
failed because of
gross error on SCSI
processor.
Error
A physical disk
failed because of
bad tag from the
device.
Error
A physical disk
failed because
command to the
device timed out.
Error
A physical disk
failed because of the
system reset.
Description
A SCSI bus or hard
disk failed.
A hard disk failed.
A SCSI bus or hard
disk failed.
Action
If a hard disk is dead,
replace it. If the error
occurs frequently, even
though hard disks are not
dead, replace the SCSI
cable or SCSI BP.
Replace the hard disk and
perform the rebuild
process.
If a Multi Dead occurred,
take corrective action
using the Multi Dead
function.
If a hard disk is dead,
replace it. If the error
occurs frequently, even
though hard disks are not
dead, replace the SCSI
cable or SCSI BP.
If a single occurrence is
logged and no other hard
disk failure is found, no
action is required because
the normal status is
restored by a recovery
process for noise and
other reasons.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents