Semi-permanent installation

SEMI-PERMANENT INSTALLATION
If required, your appliance can also be
installed semi-permanently (Fig. E).
Proceed as follows:
• Drill a hole ø 5,25 inches (134 mm) in
an outside wall or through a window
pane.
Respect the dimensions and height
of the hole given in figure F and G.
in the
in the
window
wooden
pane
kickboard
of a
French
window
F
"As special tools are required for
installation, we suggest you have
the appliance installed by speciali-
zed personnel."
E
in the wall:
you are
recommend-
ed to insulate
the section of
wall using suit-
able insulation.
• Fit the wall flange (10) into the hole.
• Fit the air exhaust hose (11) in the rel-
evant housing located on the rear
side of the appliance. (fig. A page 6).
• Fit the end of the hose (11) to the
wall flange (10) as shown in fig. G
When the hose (11) is not connected,
the drilled hole can be closed with the
flange cap (10).
For models supplied only with the strip
gasket (16) proceed as follows:
• Apply the strip gasket (16) to the
end of the exhaust hose (11) as
shown in fig. G1 then fit directly the
hose to the wall hole (Fig. G2),
respecting the measures given in
fig. G .
G1
16
NOTE: When installing the air conditioner
semi-permanently, you should leave a
door slightly open little as 1/2 " (1 cm)
to guarantee correct ventilation and
room pressure.
Keep the air hoses as short and free
of curves as possible to avoid con-
strictions.
GB
.
G
G2
7