Delta Elec. Inc.
5-9.
OPTIONS / Advanced
Press Menu to open the OSD menu. Press
move up and down in the OPTIONS menu. Select Advanced and press Enter to open the sub
menu. Press
setting.
I
TEM
Direct Power On
Auto Power Off (min)
Sleep Timer (min)
Note :
Press any keypad/IR button to restore the original timer setting when a warning message
displays.
Company Confidential
74
to change values for settings, and then press Enter to confirm the new
If the user selects On the projector will automatically power on when
AC power is supplied.
Set the projector to automatically switch off the lamp when there is no
signal after 15 minutes.
Sets the countdown timer interval. The timer will begin, with or without
a signal input. Then the projector will automatically power Off when the
sleep timer countdown stops (in minutes).
Optoma_______________________
EP7155i & EP1691i
to move to the OPTIONS menu. Press
D
ESCRIPTION
DEFAULT
Off
15
0
Delta____________