5. Installation Instructions

Cassette unit:
Cautions
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put fingers
or any other things into the inlet/outlet and
swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1. Applicable ambient temperature range:
AB092/122ACBIA, AB142/182ACBJA:
DB C
indoor
WB C
Cooling
DB C
outdoor
WB C
indoor
DB C
Heating
WB C
outdoor DB C
WB C
AB142/182ACBFA:
DB C
indoor
WB C
Cooling
DB C
outdoor
WB C
DB C
indoor
Heating
WB C
DB C
outdoor
WB C
2. If the supply cord is damaged, it must be replaced by
the manufacturer or its service agent or a similar qualified
person.
3. If the fuse on PC board is broken please change it with
the type of T3.15A /250VAC.
4. Use copper wire only. The connecting cable should
be H05RN-F 4G 0.75mm. The power cable should be
2
H05RN-F 3G 2.5mm.
All the cables shall have got the European authentication
certificate.
5. The power cord should be self-provided and it should
have got the Local authentication certificate.
11
Commercial Air Conditioner
Rated Maximum Minimum
27
32
18
19
23
14
35
43
-5
24
26
--
20
27
15
14.5
--
--
7
24
-7
6
18
--
Rated Maximum Minimum
27
32
18
19
23
14
35
43
10
24
26
--
20
27
15
14.5
--
--
7
24
-7
6
18
--
2
6. The air breaker should be all-pole switch. And the
distance between it's two connecters should be no
less than 3mm.
7. Air conditioner must use special power supply
system (above 20A), and qualified electrician makes
wiring and fixing according to wiring regulations
specified in national standard.
8. In socket, exactly distinguish earth wire with neutral
wire and it is wrong to connect them together.
9. A leakage breaker must be installed.
10. Connection method is Y-connection .If the power
cord is damaged, it must be replaced by professional
people of manufacturer or its maintenance department
or similar agency to avoid dangers.
Other Instructions
1. The waste battery shall be disposed properly. When
throwing away the waste batteries, please perform in
accordance with the local regulation.
2. The indoor unit installation height is at least 2.5m.
Model: AB182ACERA