Tool Storage - Ryobi ERC1512 Owner's Operating Manual

Table of Contents

Advertisement

surface.

TOOL STORAGE

See Figure 6 - 7.
Pneumatic accessories may be stored in the accessory
compartment.
NOTE: Always disconnect the tools from the air hose
and securely close the accessory compartment before
storage.
Certain pneumatic nailers can be mounted to the sides
of the air station using the side connect storage areas.
Framing and roofing nailers should not be stowed in these
storage areas as they are too large.
NOTE: Never rest the trigger of the nailer/stapler tool on
this storage mount.
The air station should be stored on a stable flat surface
either in the horizontal or upright position.
NOTE: Do not suspend the air station as it may result in
damage to the air station or personal injury.
AUTO/OFF
See Figure 8.
Connect the air station to a power supply. Turn the power
switch to the AUTO position to power the station on, as
shown in the start up section of the quick reference label.
NOTE: Do not run the station in the vertical position. To turn
the air station off, turn the power switch to the OFF position.
NOTE: When the station is in the AUTO position, the air
station will automatically turn back on when the tank air
pressure drops below the preset pressure limit. It will also
shut off again when the max pressure is reached.
RESETTING THE AIR STATION
When amperage into the air station exceeds the specified
amperage, the air station will automatically shut off.
1. Turn the air station off.
2. Unplug the air station to allow unit to cool and to trigger
reset.
NOTE: If the overload protector is actuated, the motor
must be allowed to cool down for 30 minutes.
3. Plug the air station into an approved outlet.
4. Turn the air station on.
English
Never exceed the pressure rating of the tool as
recommended by the manufacturer. When using
this air station as an inflation device, always follow
the maximum inflation guidelines stated by the
manufacturer of the item being inflated.
Always ensure the switch is in the OFF position and
the regulator pressure gauge reads zero Pa before
changing air tools or disconnecting the hose from
the air outlet. Failure to do so could result in possible
serious personal injury.
CONNECTING/DISCONNECTING HOSES TO THE AIR
STATION
See Figures 8 - 10.
When connecting a pneumatic air nailer or other air tool
always follow the manufacturer's recommended start-up
procedure.
When connecting/disconnecting a hose to the air station
always do the following.
1. Ensure AUTO/OFF switch is in the OFF position and
the air station is unplugged.
2. Confirm that the outlet pressure is at zero Pa by fully
turning the regulator knob counterclockwise to fully
reduce air pressure at the outlet.
NOTE: Turning the knob clockwise increases air
pressure at the outlet. Turning counterclockwise
reduces air pressure at the outlet.
3. Attach coiled air hose to coupler on the side of the
air station.
4. Connect the air station to a power supply and turn
power switch to the AUTO position.
5. Allow unit to reach max pressure as indicated on the
tank pressure gauge.
6. Set regulator to desired pressure by rotating pressure
regulator knob. The regulator pressure will appear on
the gauge marked as outlet.
To disconnect a coiled air hose:
1. Confirm that the outlet pressure is at zero bar.
2. When disconnecting a hose from 6.4 mm quick
coupler, always firmly hold release end of hose.
3. Pull back on the release sleeve on the 6.4 mm quick
coupler.
4. With a firm grip, pull out the quick-connect air fitting
that is attached to the quick coupler.
5. Attaching or disconnecting pneumatic tools from the
6
WARNING
WARNING