Software Adjustments - Icom IC-F43GT Service Manual

Uhf
Hide thumbs Also See for IC-F43GT:
Table of Contents

Advertisement

SOFTWARE ADJUSTMENT (RECEIVING)
• Select an operation using [↑] / [↓] keys, then set specified value using [←] / [→] keys on the connected computer keyboard.
• Need to adjust "S-METER ADJUSTMENT" after "RX SENSITIVITY ADJUSTMENT" is adjusted.
Otherwise, "S-METER ADJUSTMENT" will not be adjusted properly.
ADJUSTMENT
RX
1
• Operating CH
SENSITIVITY
• Connect the standard signal generator
[BPF T1],
to the antenna connector and set as:
[BPF T2]
Frequency
Level
Modulation
Deviation
• Receiving
CONVENIENT:
The BPF T1, BPF T2 can be adjusted automatically.
q-1: Set the cursor to "BPF ALL" on the CS-F33G ADJ's screen and then push [ENTER] key.
q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.
w-1: Set the cursor to one of BPF T1, T2 as desired.
w-2: Push [ENTER] key to start tuning.
w-3: Repeat w-1 and w-2 to perform additional BPF tuning.
• Operating CH
S-METER
1
[S-METER]
• Connect the SSG to the antenna con-
nector and set as:
Frequency
Level
Modulation
Deviation
• Receiving
• Set the SSG as :
2
Level
• Receiving
SQUELCH
1
• Operating CH
• Connect the SSG to the antenna con-
LEVEL
nector and set as:
[SQL]
Frequency
Level
Modulation
Deviation
• Receiving
*The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.
ADJUSTMENT CONDITION
: CH1
: 400.000 MHz
450.000 MHz
: 10 µV* (–87 dBm)
: 1 kHz
: ±3.5 kHz
or
: CH1
: 400.000 MHz
450.000 MHz
: 14 µV* (–84 dBm)
: 1 kHz
: ±3.5 kHz
: 0.45 µV* (–114 dBm)
: CH7
: 470.000 MHz
520.000 MHz
: 0.2 µV* (–121 dBm)
: 1 kHz
: ±3.5 kHz
MEASUREMENT
UNIT
LOCATION
Side
Connect the SINAD meter with
an 8 Ω load to the [SP] jack
panel
through the JIG cable.
[L]
[H]
Push the [ENTER] key on the connected computer's keyboard
to set "L2 level".
[L]
[H]
Push the [ENTER] key on the connected computer keyboard
to set "L0 level".
Side
Connect speaker to the [SP] jack
panel
through the JIG cable.
[L]
[H]
5 - 5
VALUE
Minimum distortion
level
Set "SQL level" to
close squelch.
Then set "SQL level"
at the point where
the audio signals
just appears.

Advertisement