Pll Adjustment - Icom IC-R2 Service Manual

Communications receiver
Hide thumbs Also See for IC-R2:
Table of Contents

Advertisement

5-2 PLL ADJUSTMENT

ADJUSTMENT
ADJUSTMENT CONDITION
1ST VCO
1
• Displayed frequency :
LOCK
VOLTAGE
• Receiving
(SHIFT ON)
2
• Displayed frequency :
• Receiving
(SHIFT OFF)
1
• Displayed frequency :
• Receiving
2
• Displayed frequency :
• Receiving
2ND VCO
1
• Displayed frequency :
LOCK
VOLTAGE
• Receiving
2
• Displayed frequency :
• Receiving
REFERENCE
1
• Displayed frequency :
FREQUENCY
• Receiving
DETECTOR
1
• Displayed frequency :
OUTPUT
VOLTAGE
• Connect an SSG to the antenna
connector and set as:
Level
Deviation : ± 3.5 kHz
Modulation : 1 kHz
• Receiving
*This output level of the standard signal generator (SSG) is indicated as SSG's open circuit.
493.300 MHz
282.900 MHz
0.495 MHz
493.295 MHz
430.000 MHz
493.300 MHz
(FR ch)
280.100 MHz
(tk ch)
145.600 MHz
: 1 mV
(60 dBµ)
*
MEASUREMENT
UNIT
LOCATION
RF
Connect the digital
multi-meter to the
check point LV1.
RF
Connect the digital
multi-meter to the
check point LV2.
RF
Connect
the
fre-
quency counter to
the check point F.
RF
Connect the digital
multi-meter to check
point QUAD.
5 - 3
ADJUSTMENT
VALUE
UNIT
1.9 V – 2.9 V
less than 12 V
1.4 V – 2.4 V
less than 12 V
0.4 V – 1.0 V
less than 2.5 V
546.7999 MHz –
LOGIC
546.8001 MHz
1.0 V
RF
POINT
ADJUST
Verify
[DIAL]
L21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents