DRAIN PUMP
Refer to page 4-13 for the procedure for ac-
cessing the drain pump.
1.
Unplug washer or disconnect power.
2.
Disconnect the wire connector from the
drain pump terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to each
of the drain pump terminals. The meter
should indicate between 10.5 and 14 Ω.
WARNING
Electrical Shock Hazard
Terminals
5-2
RECIRCULATION PUMP
Refer to page 4-13 for the procedure for ac-
cessing the recirculation pump.
1.
Unplug washer or disconnect power.
2.
Disconnect the wire connector from the
recirculation pump terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to each of
the recirculation pump terminals. The me-
ter should indicate between 30 and 38 Ω.
Terminals