When you think something wrong

Check the following again before asking for service. If the trouble cannot be recovered, consult your dealer.
Phenomena
The Main power is not turned on.
The power cord is disconnected.
60 seconds have not elapsed since the
Power cannot be
power was turned off.
turned on.
Inside the projector too hot.
The setting of the input source is not
No picture and
correct.
sound
Wiring to the projector is not correct.
Wiring to the projector is not correct.
Only picture is
The volume is set to minimum.
displayed with no
sound
The unit enters the mute mode.
Wiring the projector is not correct.
Only sound is
The brightness is set fully to the dark
heard without a
side.
picture
Lens cap is attached.
Color is weak and
The color and tint have been adjusted
tint is incorrect
incorrectly.
The brightness and contrast has been
Picture is dark
adjusted incorrectly.
The lamp has not been adjusted.
Picture is not clear
Focus or H.PHASE is not matched.
LAMP indicator
Trouble with the lamp.
lights red.
Cable was connected after the power
Remote control
was turned on.
mouse cannot be
RGB signal not selected.
operated.
A bright dot may be seen in the picture. This is a phenomenon peculiar to the liquid crystal and is not a problem.
A residual image may occur when the same pattern is displayed for an extended time but this is not a malfunction.
Cause
Turn the MAIN POWER switch on.
Insert the power cord into an AC socket.
When the power is turned off turn the power
switch on after waiting at least 60 seconds.
Do not block the ventilation holes.
Clean the air filter.
Use the projector under 35
Set the correct input using the input select button
of the projector or the remote control.
Connect the cable correctly.
Connect the cable correctly.
Press the VOL button or press the MENU button
and adjust the volume.
Press the MUTE button.
Connect the cable correctly.
Press the MENU button and select BRIGHT and
press the
Remove the lens cap.
Adjust the color and tint correctly.
Adjust the brightness and contrast correctly.
Replace the lamp with a new one.
Adjust the focus or H.PHASE
Turn off the power and leave for 45 minutes ;
then turn the power on again.
Be sure to perform procedure in the following order:
(1)Connect cable. (2)Turn on projector. (3)Turn PC on.
Input RGB signal and select and display input
source.
Check point
°C
temperature.
button.
Page
P.13
P.9
P.13
P.6
P.29
P.8, 10,
13, 18
P.9, 28
P.9, 28
P.10, 17
P.8, 10
P.9, 28
P.17
P.13
P.17
P.17
P.29
P.13, 17
P.32
P.23