4.
Locate the 9-pin D-type Male to 9-Pin D-type Male RS422 cable supplied with the
matrix chassis. Cut off one of the DB9 connectors and strip the wires back for
connection to the terminal strip on the RS232/RS422 converter. Connect the other
DB9 connector to the the RS422 Master female port on the VideoBloX CPU module.
This port is the third from the left port when viewing the chassis from behind.
5.
Connect the power supply provided with the HEGS5BLX keyboard to the terminal
block.
6.
Connect the power supply provided with the HVB232422 Converter to the power
terminal strip on the converter.
The keyboard should immediately power-up and display its booting screens then the
address and baud rate settings. The baud rate must be the same as that shown in the
Diagnostic Screen (section 9) for "Master" (default 19,200 Baud) and the keyboard address
should be 1. To change the baud rate speed and address, perform the procedure for
configuring the keyboard.
1.
Power down the unit and power it back up.
2.
Press the middle soft key below the LCD after
the controller counts down, while the application
screen shown to the right is displayed.
The address selection screen is displayed.
3.
Press Enter to accept the current address shown
in parenthesis or enter a new address using the numeric keys and press Enter. The
Tilt configuration is displayed.
4.
Press 1 for normal tilt operation. Press 2 to reverse the tilt operation; that is the tilt up
command sends a tilt down command to the PTZ and the tilt down command sends a
tilt up command to the PTZ. When the desired selection is displayed, press Enter.
The baud rate configuration is displayed.
5.
Press the + and - keys to scroll through the available baud rates, 1200, 9600, 19200,
and 57600. When the desired baud rate is displayed, press Enter. The default baud
rate is 19200. The controller returns to the Login screen.