Operating Faults; Service And Customer Care - DeLonghi F28313 Instructions Manual

Roto fryer
Hide thumbs Also See for F28313:
Table of Contents

Advertisement

Operating faults

Fault
The odour-eater filter is
Bad smell
saturated.
The oil has deteriorated.
The cooking liquid is
unsuitable
The oil has deteriorated
The oil
and causes too much foam.
overflows
You have immersed food
which is not sufficiently dry
in the hot oil.
The
immersed too quickly. The
oil level in the fryer is over
the maximum limit.
The deep fryer has pre-
The oil does
viously been used without
not heat up
oil in the frying bowl,
causing the thermal safety
device to break.
The basket does not rotate
Only half of the
during cooking.
basket has fried
properly.

Service and Customer Care

• If the cord is damaged it must, for safety reasons, be repaired by
De'Longhi or an authorised De'Longhi repairer in order to
avoid any risk.
• Please refer to the guarantee leaflet enclosed for service and
assistance details
Cause
basket
has
been
11
Remedy
Replace the filter.
Replace the oil or fat.
Use a good quality oil suitable for
deep frying.
Replace the oil or fat.
Dry the food well.
Immerse it slowly.
Reduce the amount of oil in the frying
bowl
Contact the Customer Experience
Team (see enclosed guarantee leaflet).
Clean the bottom of the frying
bowlClean the basket wheel guide
ring.
Roto Fryer F28313

Hide quick links:

Advertisement

Table of Contents
loading