Due to fog residue, smoke, and dust, cleaning the internal and external
optical lenses must be carried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outer
casing.
2. Use a brush to wipe down the cooling vents.
3. Clean the external portion of the optics with glass cleaner and a
soft cloth every 20 days. Situation may very. If used heavily in
clubs with lots of fog, cleaning may be required more often.
4. Clean the internal portion of the optics with glass cleaner and a
soft cloth every 30-60 days.
5. Always be sure to dry all parts completely before plugging the
unit in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
Simple Scan™
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
No light output from the unit;
1. Be sure you have connected your units into a standard 120v outlet.
2. Be sure the fuse is good.
3. Remove the lamp cover and be sure the lamps are seated in their
socket properly. Occasionally lamps become loose during ship-
ping be sure the lamps are properly seated in their sockets.
Unit does not respond to sound;
1. Low frequencies (bass) should cause the unit to react to sound.
Tapping on the microphone, quiet or high pitched sounds may
not activate the unit.
2. Be sure the blackout button on the remote control is not
engaged.
American DJ
- www.americandj.com - Simple Scan™ Instruction Manual Page 9
©
®

Cleaning

Trouble Shooting
Simple Scan™
The Simple Scan™ in the system comes with a set of four additional
dichroic colored filters and four additional different patterned gobos.
These can be interchanged at any time and allows you to customize
your system. With the additional colors and gobos your can have all
same gobos with different colors, all the same colors with different
gobos, or a mixture of any type.
To replace colors and or gobos;
1. Remove the front access cover.
2. Locate and loosen the single thumb screw directly in front of
the lamp.
3. Pull out the gobo assembly.
4. Once the gobo assembly has been removed, remove the
retaining ring by pitching the ends inwards.
5. The gobo and color filter will now easily pop out. Remove and
replace the color and/or gobo with your desired replacement.
6. When reassembling be sure the gobo goes in first and the
color filter goes on second.