S t e p 1 .
Disconnect power supply cord
from power source.
Remove three (3) screws and
control box cover on the back
of the heater.
Step 2.
Disconnect ground wire (green
wire) from the power supply
cord bracket.
Step 3.
Disconnect two power supply
wires from right side of the ter-
m i n a l .
Step 4.
Squeeze strain relief with the
adjustable pliers to remove
plastic bushing from the pow-
er supply cord bracket.
Remove the power supply
cord.
Step 5.
Insert the power supply cable
from junction box and connect
ground wire to the power sup-
ply cord bracket and power
wires to the terminals.
Step 6.
Affix the control box cover to
the heater and insert screws.
N OT E : Em erg en cy po we r su pp ly a nd u se of 1 2V DC ba tteries and an inverte r. Co nsult you r d eale r
before attempting to use a battery/inverter system to provide power for your Laser heater.
T hes e u nits re qu ire tr ue sine w ave p ow er fo r prop er lo ng-term ope ra tion. Some mo d if ie d sine
wave inverters can be used to provide short-term emergency power but some types of modi-
fied sine wave inverters will cause damagg to the electrical components of the heater. Several
inverter manufacturers offer true sine wave inverters which should operate the unit without any
probl ems if p ro pe rly size d a n d co nfi g ur ed . l f you h ave any que sti ons abo ut app ropria t e p ower
supply, consult your authorized TOYOSTOVE dealer.