Start-Up Rinsing Procedure - Hamilton Beach SA-HB-40-DB-CERT Owner's Manual

Table of Contents

Advertisement

Start-up Rinsing Procedure

Start-Up Rinsing Procedure
(Bypass valve is optional)
1. With the plumbing, drain line, and overflow
connections completed, slowly open the water
supply allowing the lines to pressurize.
Note: The optional bypass should still be in bypass mode as
shown in Figure 9.
Outlet
2. With the control valve unplugged, manually
advance the control valve by depressing the drive
gear and rotating the main system gear to the
purge position. (See Figure 10.)
3. Slowly open the inlet valve (only) on the bypass
valve allowing the system to pressurize. It is
normal to hear air blowing to the drain during this
procedure.
10 | Hamilton Beach Owner's Manual
Inlet
Figure 9
Figure 10
Once the air clears and water begins to run to the
drain, open the inlet valve (only) to the full open
position and allow the water to run to the drain in
purge for a minimum of 20 minutes. (See Figure
11.)
Outlet
4. After the 20-minute purge cycle, manually
advance the main gear to the backwash cycle and
allow to run for a minimum of 10 minutes. (See
Figure 12.)
Note: when advancing the main gear manually while under
water pressure it is normal for the gear to encounter resistance
as the valve chambers depressurize. If resistance occurs,
pause five seconds to allow the valve to depressurize before
advancing to the next step.
Inlet
Figure 11
Figure 12