Garrett PD 6500i User Manual page 39

11684xx
Hide thumbs Also See for PD 6500i:
Table of Contents

Advertisement

PD 6500i User MANUAL
RX OPTIC FAIL: Ensure the openings for the optical sensor (located inside both side panels
at approximately 30" from the floor) are not blocked.
RX A or B ZN # BAL FAIL: Ensure there is no large metal object near the PD 6500i.
If the self-test reveals a failure that severely limits or prohibits the PD 6500i's performance, the
alarm will sound, the LED display will flash and the message SYSTEM FAILURE will appear on
the LCD. The LED will continue flashing until the power is turned off or the failure is
remedied.
The Operator should inform the Supervisor of any problems that occur.
5.2.3
resPONDING TO ALArMs
If a patron triggers an alarm and the alarm light appears, the Operator should instruct the
individual to step outside the walk-through and remove any metal objects from their body
and/or clothing. The Operator should then either scan the patron with a hand-held metal
detector, such as a SuperScanner of SuperWand or ask the person to re-enter the
walk-through.
If an alarm sounds after the patron reenters the walk-through, he or she must be re-scanned
with a hand-held metal detector.
The pinpoint lights facilitate the screening process by indicating the location of ALL alarm-
able objects within 33 pinpoint areas. In cases, where there is more than one object, the
lights appear in each array that requires investigation. This enables the Operator to know from
which area(s) objects require removal and to concentrate on the problem areas when hand
scanning, resulting in improved overall security and increased throughput.
© 2008 Garrett Metal Detectors
39
PN 1532010 REV F1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

11684 series1168420

Table of Contents