The user may press the + / - touchpads to scroll through the options:
ZONE LIGHT: OFF
ZONE LIGHT: 2 SEC
ZONE LIGHT: 3 SEC
ZONE LIGHT: 4 SEC.
3.5.16
ALArM TIMe
Sets the duration for audible alarms for 1, 2, 3 or 4 seconds. The user may use the + / -
touchpads to adjust the time between 1-SEC to 4-SEC in 1 second increments.
3.5.17
Ir ANALYsIs
Infrared sensors have been designed to help prevent false alarms caused by nearby
external moving metallic materials such as wheelchairs, elevators, persons possessing
metal, etc., and when outdoors by wind causing the unit to rock and then alarm. When IR
Analysis is on, the above circumstances will not cause the detector to audibly alarm when no
one is passing through the unit. When IR Analysis is off, the unit may audibly alarm under
these circumstances even when no one is passing through the unit. Although useful, the IR
Analysis is not required for operation and may be disabled if desired.
IR ANALYSIS, shown either ON or OFF, will appear on LCD. Press the minus (–) touchpad
to disable or (+) touchpad to activate.
3.5.18
COUNT DIreCTION
CNT DIR is used to select the way in which traffic flow will be counted.
FWD ONLY counts patrons passing in the normal forward direction only; passing in the
reverse direction has no affect on count.
REV ONLY counts patrons passing in the reverse direction only and does not count patron
passes made in the forward direction.
SUB REV counts patrons passing in the forward direction and subtracts from the count for
patrons passing in the reverse direction.
BIDIRECT counts patrons passing in both directions.
3.5.19
LANGUAGe
LANGUAGE, which indicates the current language setting, appears on the LCD. If the user
is authorized to change the language setting, the user may scroll through the language
selections using the + / - touchpads. Choose from: English, Spanish, Turkish, German, Czech,
French, Polish or Italian.
3.5.20
rX BALANCe
RX BAL refers to the balance level of the receiving antennas and is a "view only" item. Any
number less than 50 is acceptable. A number greater than 50 will elicit the message, RX BAL
#, and the pinpoint lights within the problem zone will illuminate. Should this occur, ensure
that there is no large metal object adjacent to the PD 6500i . Then, ensure that the balance
number has fallen below 50 and the corresponding pinpoint lights are off. (Refer to section
6.2 for more help in resolving this issue if necessary.)
© 2008 Garrett Metal Detectors
PD 6500i User MANUAL
26