E RR O R CON TEN T S
Model : MW18C3F
Error
Serial signal error
Indoor unit thermistor error
Outdoor unit thermistor error
Indoor unit control error
Outdoor unit control error
Indoor fan motor error
Refrigerant cycle error
Optional function error
Model information error
2006.04.07
Display
Error
Operation
Timer LED
LED
2 flash
Serial signal (reverse) error, at operation start up
3 flash
Serial signal (reverse) error, during oeration
Normal
4 flash
Serial signal (forward) error, at operation start up
5 flash
Serial signal (forward) error, during operation
2 flash
Indoor temperature thermistor open / short
2 flash
3 flash
Heat exchanger middle thermistor open / short
2 flash
Discharge thermistor open / short
3 flash
3 flash
Heat exchanger thermistor open
4 flash
Outdoor temperature thermistor open / short
2 flash
Forced automatic SW welded
3 flash
Main relay welded
4 flash
4 flash
Power interruption error
7 flash
VDD permanent stop protection
8 flash
reverse VDD permanent stop protection
2 flash
Current trip error
3 flash
CT abnormal
5 flash
5 flash
Compressor location detection error
6 flash
Outdoor unit fan drive system abnormal
2 flash
Abnormal lock
6 flash
3 flash
Abnormal rotation
2 flash
Discharge Temperature abnormal
7 flash
3 flash
Cooling high pressure abnormal rise
8 flash
4 flash
PFC circuit error
0.1 sec on/off 0.1 sec on/off
Model information error
10