Terminal Block - Henny Penny HCS-2 Technical Manual

Humidified counter warmer
Hide thumbs Also See for HCS-2:
Table of Contents

Advertisement

2-17. TERMINAL BLOCK

2-14
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control side panel.
3. Remove the electrical wires from the terminal block.
4. Remove five nuts holding the mounting plate to the end
channel.
5. Remove the screws holding the contactor to the mounting plate.
Step 5
6. Install a new terminal block in reverse order.
7. Replace the end panel.
8. Turn on the power at the breaker box.
Model HCS-2,HCW-3/HCW-5/HCW-8
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcs-5Hcw-8Hcw-2Hcw-3Hcw-5

Table of Contents