Location; Drain Connection - Henny Penny CBC/CBR-103 Operator's Manual

Cold bases
Hide thumbs Also See for HENNY PENNY CBC/CBR-103:
Table of Contents

Advertisement

2-4. LOCATION

2-5. REFRIGERATION
INFORMATION
UL Specs
CE Specs

2-6. DRAIN CONNECTION

303
Place the cold bases in an area where product can be loaded and
unloaded without interruption. For proper operation, level the unit
by adjusting the bolts under the base, and leave 3 feet (91.44 cm)
clearance behind the unit for ventilation and service.
For maximum efficiency, units should be operated in an air-condi-
tioned environment, with maximum air temperature of 75° F
(24° C), and 55% relative humidity.
Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system need to settle before operating the compressor, or
damage to the compressor could result.
Refrigerant Type Amount of Refrig.
CBC-103
R22
CBC-104
R22
CBC-105
R22
CBC-106
R22
CBC-107
R22
CBC-103
R134A
CBC-104
R134A
CBC-105
R134A
CBC-106
R134A
CBC-107
R134A
The cold bases-remote (CBR), require 1 inch (25.4 mm) drain
connection. Cold bases with condensing units (CBC) do not
require a plumbed drain.
Model CBC/CBR-103,104,105,106,107
Design Pressure
High
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
2.5 lbs (1.134 kg)
440psig
(30.3 bar) (11.2 bar)
1.76 lbs (0.800 kg)
440psig
(30.3 bar) (11.2 bar)
2.20 lbs (1.00 kg)
440psig
(30.3 bar) (11.2 bar)
2.65 lbs (1.200 kg)
440psig
(30.3 bar) (11.2 bar)
3.09 lbs (1.400 kg)
440psig
(30.3 bar) (11.2 bar)
3.53 lbs (1.600 kg)
440psig
(30.3 bar) (11.2 bar)
Low
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
162 psig
2-3