Henny Penny  CBC/CBR-103 Operator's Manual
Henny Penny  CBC/CBR-103 Operator's Manual

Henny Penny CBC/CBR-103 Operator's Manual

Cold bases
Hide thumbs Also See for HENNY PENNY CBC/CBR-103:

Advertisement

Quick Links

Henny Penny
Cold Bases
Model CBC/CBR-103
Model CBC/CBR-104
Model CBC/CBR-105
Model CBC/CBR-106
Model CBC/CBR-107
OPERATOR'S MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Henny Penny HENNY PENNY CBC/CBR-103

  • Page 1 Henny Penny Cold Bases Model CBC/CBR-103 Model CBC/CBR-104 Model CBC/CBR-105 Model CBC/CBR-106 Model CBC/CBR-107 OPERATOR’S MANUAL...
  • Page 2 0 TO 3 YEARS: During this time, any frypot that fails due to manufacturing or workmanship is- sues will be replaced at no charge for parts, labor, or freight. Henny Penny will either install a new frypot at no cost or provide a new or reconditioned replacement fryer at no cost.
  • Page 3: Table Of Contents

    Section Section 1. INTRODUCTION ... 1-1 1-1. Henny Penny Cold Bases ... 1-1 1-2. Features ... 1-1 1-3. Proper Care ... 1-1 1-4. Assistance ... 1-1 1-5. Safety ... 1-2 Section 2. INSTALLATION... 2-1 2-1. Introduction ... 2-1 2-2. Unpacking ... 2-1 2-3.
  • Page 4: Section 1. Introduction

    Insulated-well with high pressure injected polyurethane foam • Automatic defrost cycles As in any unit of food service equipment, the Henny Penny cold bases does require care and maintenance. Requirements for the maintenance and cleaning are contained in this manual and must become a regular part of the operation of the unit at all times.
  • Page 5: Safety

    1-5. SAFETY Model CBC/CBR-103,104,105,106,107 The Henny Penny cold bases have many safety features incorporated. However, the only way to ensure a safe operation is to fully understand the proper installation, operation, and maintenance procedures. The instructions in this manual have been prepared to aid you in learning the proper procedures.
  • Page 6: Section 2. Installation

    The Henny Penny cold base has been tested, inspected, and expertly packed to insure arrival at its destination in the best possible condition. The grids are packed separately inside the unit.
  • Page 7: Electrical

    2-2. UNPACKING (Continued) 2-3. ELECTRICAL Model CBC/CBR-103,104,105,106,107 Take care when moving the unit to prevent personal injury or damage to the refrigeration system. The units weigh between 400 (182 kg) and 580 lbs. (263 kg). Peel off any protective covering from exterior of the cabinet. Install the grids into unit.
  • Page 8: Location

    2-4. LOCATION 2-5. REFRIGERATION INFORMATION UL Specs CE Specs 2-6. DRAIN CONNECTION Place the cold bases in an area where product can be loaded and unloaded without interruption. For proper operation, level the unit by adjusting the bolts under the base, and leave 3 feet (91.44 cm) clearance behind the unit for ventilation and service.
  • Page 9: Compressor Size And Load

    2-7. COMPRESSOR SIZE AND LOAD 2-8. FOOT PRINT DRAWING DRAIN & REFRIGERATION CONNECTIONS Model CBC/CBR-103,104,105,106,107 Model CBC Motor HP CBR Motor HP CBC/ BTU Load R-22 2830 2830 3840 3840 3840 BTU load sized at evaporator temperature + 20 F or -6 C. CBR MODELS R-134a R-22 R-134a...
  • Page 10: Fluorescent Lighting And Lamp Replacement

    2-9. FLUORESCENT LIGHTING AND LAMP REPLACEMENT Model CBC/CBR-103,104,105,106,107 Model of Lights CBR/CBC-103 CBR/CBC-104 CBR/CBC-105 CBR/CBC-106 CBR/CBC-107 Replacement: UL Units 1. Pull the lamp out of the sockets. 2. Remove the lamp guard caps. 3. Install new fluorescent bulb in reverse order. CE Units 1.
  • Page 11: Hot Or Cold Top On A Cold Base Installation Instructions

    2-10. HOT or COLD TOP ON A COLD BASE INSTALLA- TION INSTRUCTIONS Figure 2-1 Figure 2-2 Figure 2-3 Model CBC/CBR-103,104,105,106,107 1. Remove bolts securing the top to the skid, and save bolts for later use. 2. Carefully set top on top of the cold base. Take care when moving the unit to prevent personal injury or damage to the refrigeration system.
  • Page 12: Section 3. Operation

    3-1. INTRODUCTION 3-2. OPERATING CONTROLS Fig. Item Description Power Switch Digital Display SECTION 3. OPERATION This section provides explanations of all controls, along with operating procedures and daily maintenance. Read the Introduction, Installation and Operation Sections before operating the unit. Wait at least 4 hours before plugging the unit into an electrical supply.
  • Page 13 Model CBC/CBR-103,104,105,106,107 3-2. OPERATING CONTROLS (Continued) Figure 3-1...
  • Page 14: Basic Operation

    3-3. BASIC OPERATION 3-4. CLEANING Model CBC/CBR-103,104,105,106,107 Turn power switch to ON position. Wait for temperature to reach operating temperature, 36 to 38° F (2.2 to 3.3° C). Place chilled, prepackaged product into case. Do not stock product in the case beyond the load height limit of 9 inches (23 cm), or over the front edge.
  • Page 15 3-4. CLEANING (Continued) Model CBC/CBR-103,104,105,106,107 Every 3 Months: 1. Remove all electrical power supplied to the unit by unplug- ging the power cord from the wall, or by turning off the wall circuit breaker. 2. Remove all product from the unit. 3.
  • Page 16: Programming

    3-5. PROGRAMMING Model CBC/CBR-103,104,105,106,107 1. Press and hold for 4 seconds. The “DEF/SET” light flashes in display. Temperature Setpoint 2. Press the to change the temperature setpoint, within 5 seconds. After 5 seconds, the last entered setpoint stays in memory. Other Parameters 3.
  • Page 17 3-5. PROGRAMMING Continued Model CBC/CBR-103,104,105,106,107 dS: (defrost system (computation)) dF=digifrost feature; defrost start time based on total compressor running time. rt=real time; defrost start frequency, based on real time dI: (defrost interval) defrost frequency in hours, based on the selection of “dS” dE: (defrost endurance) total (maximum) length of a defrost cycle, expressed in minutes.
  • Page 18 Model CBC/CBR-103,104,105,106,107 DIAGRAM FOR CBC MODEL...
  • Page 19 Model CBC/CBR-103,104,105,106,107 DIAGRAM FOR CBR MODEL...
  • Page 20 Model CBC/CBR-103,104,105,106,107 230V-50Hz-1ph-CE...
  • Page 21 Item Part 23969 Refrigeration/Condensing unit 1/3 HP - CBC-103/104-UL 23968 Refrigeration/Condensing unit 1/2 HP - CBC-103/104-CE 23968 Refrigeration/Condensing unit 1/2 HP - CBC-105/106/107 23978 Evaporator - CBC/CBR-103 23977 Evaporator - CBC/CBR-104 23976 Evaporator - CBC/CBR-105 23975 Evaporator - CBC/CBR-106 23974 Evaporator - CBC/CBR-107 √...

Table of Contents