MULTIQUIP GA-6H Operation And Parts Manual page 19

Portable generators honda gasoline engine
Table of Contents

Advertisement

Figure 3E. Generators Components
12. Fuel Cock Lever – Turn this lever downward to start
(down)the flow of fuel into the carburetor. Turn upward to
stop ( up ) the flow of fuel.
13. Spark Plug – Provides spark to the ignition system. Set
spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean
spark plug once a week.
14. Muffler/Heat Shield – Used to reduce noise and emissions.
NEVER touch this heat shield when the generator/welder
is in use. Always allow time for the generators to cool down
before performing maintenance.
15. Choke Lever – Used for starting the engine. Close the
choke lever when starting a cold engine or in cold weather
conditions. The choke enriches the fuel mixture. Open the
choke lever if starting a warm engine or in warm weather
conditions.
16. Recoil Starter (pull rope) – Manual-starting method. Pull
the starter grip until resistance is felt, then pull briskly and
smoothly.
17. Engine Oil Filler Cap – Remove this cap/dipstick when
the adding of engine oil is required. See Table 5 for
recommended type engine oil.
GA-6H/GA-6HA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/02/05) — PAGE 19
GA-6H/GA-6HA — CONTROLS AND INDICATORS
18. Engine Oil Drain Plug – Remove this drain plug when
19. Air Cleaner – Prevents dirt and other debris from entering
20. Fuel Tank Cap – Remove this cap to add unleaded
21. Fuel Gauge – This gauge is located on top of the fuel tank.
22. Fuel Tank – Fuel tank capacity is 5 gallons (19 liters).
on level ground. Placing the generators on level ground will
ensure that the low oil sensor will function properly.
draining of the oil from the engine crankcase is required.
Fill with recommeded type oil as listed in Table 6.
the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element. NEVER run the
engine without an air cleaner.
gasoline to the fuel tank. Replenish with clean unleaded
gasoline. Make sure cap is tightened securely. DO NOT
over fill.
Read this gauge to determine when fuel is low .
This HONDA engine is equipped
with a low oil shutdown capability. A
NOTE
built in sensor will automatically turn
off the engine should the oil level fall
below a safe operating condition.
Make sure the generators is placed