Checking Gas Connections - Desa VVSR18 Owner's Operation And Installation Manual

Vented decorative natural gas logs
Table of Contents

Advertisement

INSTALLATION
6

Checking Gas Connections

Hearth Kit Assembly and Installation
INSTALLATION
Continued
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after installing
or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all
leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect log set and its individual equipment shutoff valve
from gas supply piping system.
2. Cap off open end of gas pipe where equipment shutoff valve
was connected.
3. Pressurize supply piping system by either using compressed
air or opening main gas valve located on or near gas meter.
4.
Check all joints of gas supply piping system. Apply noncorrosive
leak detection fluid to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect log set and equipment shutoff valve to gas supply.
Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 5).
2. Pressurize supply piping system by either using compressed
air or opening main gas valve located on or near gas meter.
3. Check all joints from gas meter to equipment shutoff valve
(see Figure 5). Apply noncorrosive leak detection fluid to gas
joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Figure 5 - Checking Gas Joints
For more information, visit www.desatech.com
For more information, visit www.desatech.com
HEARTH KIT ASSEMBLY AND INSTALLATION
Kit Assembly - Single and Dual-Flame Only
1. Determine which side the gas line will be coming into the fireplace.
NOTICE: Triple-burner models CBL18/24 or BFLT18/24
come preassembled with gas inlet on right side of
burner pan. DO NOT attempt to reposition burner on
triple-burner models. If your fireplace supply is on the
left side, a longer 3/8" flex line should be purchased and
routed behind burner pan and away from flame area.
2. Using a hammer and screw driver, remove knockout plug from
3. Unscrew burner inlet fitting from burner manifold.
4. Place burner manifold in pan with threaded opening facing
5. Using thread sealant (resistant to the action of propane/LP
Knockout
Plugs
Equipment
Shutoff Valve
Gas Meter
Front Burner
Figure 6 - Installing Burner
the side of the pan that corresponds to the gas line (see Figure 6).
open knockout plug.
gas) on larger end of fitting, screw the burner inlet fitting
through hole and into burner manifold (see Figure 6). Tighten
using a wrench. If using propane/LP gas, see Propane/LP
Gas Conversion, page 8.
Burner Manifold
Knockout
Plugs
Burner Pan
Burner Inlet
(Front)
Fitting
SINGLE-BURNER
Burner Pan
(Front)
TRIPLE-BURNER
Nut
Burner Clamp
Burner Pan
Burner Inlet
(Front)
Fitting
Screw
DUAL-FLAME
Burner
Gas Connection
Manifold
Must Be On Right
Side For Triple
Burner
Burner Inlet
Fitting
901265-01K