Wiring Diagrams - Hunter 43860 Installation And Operation Manual

Touchscreen programmable thermostat 2 stage heat/2 stage cool
Table of Contents

Advertisement

WIRING DIAGRAMS

Number of wires connected depends on the HVAC system requirement.
• 4-wire Heat/Cool System (single stage): RH (jumper between RH and Rc/R),
Y1, W1, G
• 5-wire Heat/Cool System (single stage): RH, Rc/R (remove jumper between RH
and RC/R), Y1, W1 G.
• 2-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1
• 3-wire Heat only (single stage): RH (jumper between RH and Rc/R), W1, G
• 3-wire Cool only (single stage): RH (jumper between RH and Rc/R), Y1, G

44002-01 r060607