  • Page 1 INSTALLATION MANUAL SH09BWHA Series SH12BWHA Series Split-type Air Conditioner (Cooling and Heating) E DB98-26315A(1)
  • Page 2: Safety Precautions

    Safety Precautions The following safety precautions must be taken when using your air conditioner. Risk of electric shock. Can cause injury or death. Disconnect all WARNING remote electric power supplies before servicing, installing or cleaning. This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
  • Page 3: Table Of Contents

    Contents REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner .......... Air Conditioner and Accessories ..............NSTALLING THE Fixing the Installation Plate ................Purging the Unit..................... Connecting the Assembly Cable ..............Installing and Connecting the Indoor Unit Drain Hose........Installing and Connecting the Outdoor Unit Drain Hose .......
  • Page 4: Deciding On Where To Install The Air Conditioner

    Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: Combustible gases Saline air Machine oil...
  • Page 5 Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. 300 mm or more 125 mm 125 mm or more or more Wrap the refrigerant pipes and the drain This drain direction is selectable hose up in the absorbent pad and the to left or right.
  • Page 6: Air Conditioner And Accessories

    Air Conditioner and Accessories The following accessories are supplied with the air conditioner. The quantities are indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Batteries for Owner’s Instruction Installation Manual (1) Remote Control (2) Booklet (1) Accessories in the Outdoor Unit Case 4-wire...
  • Page 7: Fixing The Installation Plate

    Fixing the Installation Plate Before fixing the installation plate to a wall or window frame, you must determine the position of the 65 mm hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit.
  • Page 8: Connecting The Assembly Cable

    Connecting the Assembly Cable The outdoor unit is powered from the indoor unit via the assembly cable. If the outdoor unit is more than five metres away from the indoor unit, the cable must first be extended to a maximum of 15 metres. Extend the assembly cable if necessary.
  • Page 9: Installing And Connecting The Indoor Unit Drain Hose

    Installing and Connecting the Indoor Unit Drain Hose Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through the 65 mm hole drilled in the wall, check that none of the following situations occur.
  • Page 10: Installing And Connecting The Indoor Unit Assembly Piping

    Installing and Connecting the Indoor Unit Assembly Piping There are two refrigerant pipes of different diameters: A smaller one for the liquid refrigerant A larger one for the gas refrigerant A short length of piping is already fitted to the air conditioner. You must extend this piping using assembly piping (optionally supplied).
  • Page 11: Cutting/Extending The Piping

    Cutting/Extending the Piping 7.5 metres of piping is supplied with the air conditioner(Optional). This length can if necessary be: Extended to a maximum of 15metres Shortened as required If more than 7.5 metres of piping is required: The assembly cable must also be extended You can install 15m of connecting pipe to the maximum, and you don’t have to charge any additional refrigerant.
  • Page 12: Connecting Up And Purging The Circuit

    Connecting Up and Purging the Circuit The outdoor unit is loaded with sufficient R410A refrigerant for 7.5 metres of piping. The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling/heating capacity and could lead to a malfunction.
  • Page 13: Performing Leak Tests

    Performing Leak Tests Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks. To check for gas leaks on the... Then, using a leak detector, check the...
  • Page 14: Fixing The Outdoor Unit In Position

    Fixing the Outdoor Unit in Position The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground).
  • Page 15: Explaining Operations To The Owner

    Explaining Operations to the Owner Before leaving the premises on which you have installed the air conditioner, you should explain the following operations to the owner, making reference to the appropriate pages in the owner’s instruction booklet. How to start and stop the air conditioner. How to select the operating mode and adjust the temperature and fan settings.