Canadian Equipment Requirements
This digital apparatus does not exceed the (Class A/Class
B)* limits for radio noise emissions from digital apparatus
set out in the Radio Interference Regulations of the
Canadian Department of Communications. Le present
appareil numerique n'emet pas de bruits radioelectriques
depassant les limites applicables aux appareils numeriques
(de la class A/de la class B)* prescrites dans le Reglement
sur le brouillage radioelectrique edicte par le ministere des
Communications du Canada.
This device complies with RSS-210 of Industry and Science
Canada. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this
device must accept any interference, including interference
that may cause undesired operation of the device.

INSTALLATION INSTRUCTIONS

Installing Electrical Service to the Junction Box
WARNING
Shock hazard.
• Turn electrical power off at the circuit before
starting work.
NOTE: Some appliances do not have a cover plate. In-
stead, there is a hole through which the Romex clamp is
attached to the outer wrap.
1. Remove the electrical cover plate from the lower side
of the fi replace. Remove the knock-out from the plate
and attach the Romex clamp (screws to the outside).
See Figure 1.
ON/OFF
SWITCH
REMOTE SWITCH
PIGTAIL
RED
BROWN
WALL
Figure 1
SWITCH
2. Feed the electrical service wires through the Romex
clamp and secure the wires to the clamp.
3. Using the wire nuts provided, connect the service wires to
the junction box. The black wires to the black service wire,
the white wires to the white service wire, and the service
ground wire to the ground stud of the junction box.
4. Reattach the cover plate to the outside of the fi replace.
REMOTE
RECEIVER
VALVE
Shock hazard.
• Leave electrical power off at this time.
• Do not restore power until the remote control
system is completely installed.
REMOTE RECEIVER
• Damage to receiver possible from elevated temperatures.
• The remote receiver should be positioned close to front
in right or left corner where ambient temperatures do not
exceed 170º F.
The remote receiver is powered by 110-120VAC. It plugs
into a standard polarized duplex receptacle.
Locating Receiver and Operating Functions
This remote receiver can be positioned under the fi rebox
in the control compartment of the fi replace if ambient tem-
peratures do not exceed 170
to control the following components:
• Gas Valve - Millivolt .................................................Red
• Fan/Blower - 110 VAC .............................Plug from Fan
• Flame Controller - HI/LO solenoid ..................... Orange
RECEIVER WIRING INSTRUCTIONS
Incorrect wiring connections WILL cause damage to the
gas valve or electronic module operating the gas appliance
and may also damage the remote receiver.
Wiring Flame Function
Connect the remote receiver by connecting the two red
wires leading from the remote receiver to the red and
brown remote wires labeled "FOR USE WITH REMOTE
OR WALL SWITCH ONLY". See Figure 2 or alternate wiring
diagrams on page 10.
ON/OFF
SWITCH
REMOTE SWITCH
PIGTAIL
RED
BROWN
SWITCH
Figure 2.
2
WARNING
CAUTION
0
F. This system is designed
REMOTE
RECEIVER
WALL
Wire Colors
VALVE

Advertisement