Valve Access And Service - Heat & Glo Dakota 42-CE Installer's Manual

Installation and operation
Table of Contents

Advertisement

A. Valve Access and Service
The gas valve can be accessed behind the cement
refractory panel on the right side of the fi replace.
Lift doors out and set aside. There is a washer under each
door. Be careful not to lose the washers.
Figure 11.1 Lift Out Doors
Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
Remove two screws on side of pilot shield and remove
shield.
Figure 11.2 Remove Pilot Shield
Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.
Figure 11.3 Loosen Refractory Retaining Strip
WASHER
WASHER
Heat & Glo Lifestyle Collection • Dakota 42-CE • 4036-915 Rev I • 11/07
Remove the inside valve access panel by lifting it up and
out.
Figure 11.4 Remove Valve Access Panel
Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
Figure 11.5 Remove Exterior Valve Access Panel
Loosen lower pressure tap screw before attaching
manometer. Start up the fi replace to verify the pressure
and adjust as necessary. Reverse these steps to
reassemble before log positioning.
Note: Pressure tap screws must be re-tightened.
Figure 11.6 Connect Manometer