TROUBLESHOOTING
(BEFORE CALLING FOR SERVICE)
If your air conditioner does not work properly, first check the following
points before requesting service. If it still does not work properly,
contact your dealer or service center.
Trouble
Possible Cause
Air conditioner does
1. Power failure.
not run at all.
2. Leakage circuit
breaker tripped.
3. Line voltage is too
low.
4. Batteries in remote
controller have run
down.
OPERATION lamp
Trouble in system.
blinks and air
conditioner does not
operate.
Compressor runs but
Obstruction in front of
soon stops.
condenser coil.
(Outdoor Unit)
Poor cooling (or
1. Dirty or clogged air
heating) performance.
filter.
2. Heat source or
many people in
room.
3. Doors and/or
windows are open.
4. Obstacle near air
intake or air
discharge port.
5. Thermostat is set
too high for cooling
(or too low for
heating).
6. (Outdoor
temperature is too
low for heating.)
Clicking sound is
In heating or cooling
heard from the air
operation, any plastic
conditioner.
parts may expand or
shrink due to a
sudden temperature
change. In this event,
a clicking sound may
occur.
OPERATION lamp
The use of cellular
lights but outdoor unit
phones near the air
will not run.
conditioner may cause
disturbance to its
normal operation.
TIMER lamp blinks
FLOAT SWITCH is
(3 sec. interval) and
actived.
air conditioner does
not operate.
16
The air conditioner is operable within the temperature ranges as
listed below:
COOLING
Remedy
1. Restore power.
2. Contact service
center.
3. Consult your
electrician or
dealer.
HEATING
4. Replace batteries.
Contact service
center.
A separately sold wired remote controller (CZ-RD515U)
used with this air conditioner is also available. If you wish
Remove obstruction.
to use the wired remote control function, you will need to
purchase the optional wired remote controller.
1. Clean air filter to
improve airflow.
2. Eliminate heat
source if possible.
3. Shut them to keep
the heat (or cold)
out.
4. Remove it to ensure
good airflow.
5. Set the temperature
lower (or higher).
6. (Consult your
dealer or try to use
another heat
appliance.)
This is normal, and
the sound will soon
disappear.
1. Turn off the power
then restart the air
conditioner after a
while.
2. Consult your dealer.
Contact service
center.

OPERATING RANGE

Temperature
Indoor air
temperature
Max.
95 °F DB /
71 °F WB
Min.
67 °F DB /
57 °F WB
Max.
80 °F DB /
67 °F WB
Min.
– DB / – WB
WIRED REMOTE CONTROLLER
Outdoor air
temperature
115 °F DB
For Single use
0 °F DB
For Multiple
use
14 °F DB
75 °F DB /
65 °F WB
– DB / 0 °F WB