CHIMNEY REqUIREMENTS

WARNING
Fire Risk.
Follow Chimney Connector Manufacturer's
Instructions for Proper Installation.
ONLY use connector:
Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
Attic or roof space
Closet or similar concealed space
Floor or ceiling
Maintain minimum clearances to combustibles
Non-Combustible
Firestopping
Material
2 inch
(51mm)
Floor
(second Story)
Figure 7.1
Minimum 2 inch (51mm) clearance
from combustible material
and insulation
ceiling
Figure 7.2
September 1, 2008
Firestopping
Floor
Ceiling
Caulk
Minimum 1 inch (25mm)
clearance from exterior
chimney to sheathing
Non-combustible
fire stopping material
OVALIZING ROUND STAINLESS STEEL
Ovalizing round stainless steel liners to accommodate the
liner passing through the damper region of a fireplace is an
allowable and acceptable practice.
Ensure that the ovalization is minimized to the extent
required to fit through the damper.
Fire Risk.
Do NOT pack insulation or other combustibles
between spacers.
ALWAYS maintain specified clearances around venting and
spacers.
Install spacers as specified.
Failure to keep insulation or other material away from vent
pipe may cause fire.
CHIMNEY HEIGHT
At least  ft
(91cm)
Figure 7.3 - 2-10-3 Rule
CHIMNEY TOp VIEW
1/2" (12.7mm) airspace
Foundation
Figure 7.4
7007-161H
2700-I WOOD INSERT (ACT)
LINERS
WARNING
10 ft
(05cm)
At least 2 ft
(61cm)
5/8" (16mm)
Fireclay Flue
FLUE
Chimney Wall
4" (102mm)
Nominal
Liner